A microfabricated platform to measure and manipulate the mechanics of engineered cardiac microtissues.

Thomas Boudou, Wesley R Legant, Anbin Mu, Michael A Borochin, Nimalan Thavandiran, Milica Radisic, Peter W Zandstra, Jonathan A Epstein, Kenneth B Margulies, Christopher S Chen

Abstract read
In one paragraph

Article in Tissue engineering. Part A, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 251 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
251citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

251 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. A microfluidic rheometer for tumor mechanics and invasion studies.bioRxiv : the preprint server for biology · 2025
    Article
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article

191 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Thomas BoudouDepartment of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Wesley R Legant
Anbin Mu
Michael A Borochin
Nimalan Thavandiran
Milica Radisic
Peter W Zandstra
Jonathan A Epstein
Kenneth B Margulies
Christopher S Chen

Funding

Endogenous Cardiac Repair in HumansR01HL089847 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI MARGULIES, KENNETH BER · 2009 to 2012
$1.9M
6 · The paper itself

Abstract

Engineered myocardial tissues can be used to elucidate fundamental features of myocardial biology, develop organotypic in vitro model systems, and as engineered tissue constructs for replacing damaged heart tissue in vivo. However, a key limitation is an inability to test the wide range of parameters (cell source, mechanical, soluble and electrical stimuli) that might impact the engineered tissue in a high-throughput manner and in an environment that mimics native heart tissue. Here we used microelectromechanical systems technology to generate arrays of cardiac microtissues (CMTs) embedded within three-dimensional micropatterned matrices. Microcantilevers simultaneously constrain CMT contraction and report forces generated by the CMTs in real time. We demonstrate the ability to routinely produce ~200 CMTs per million cardiac cells (<1 neonatal rat heart) whose spontaneous contraction frequency, duration, and forces can be tracked. Independently varying the mechanical stiffness of the cantilevers and collagen matrix revealed that both the dynamic force of cardiac contraction as well as the basal static tension within the CMT increased with boundary or matrix rigidity. Cell alignment is, however, reduced within a stiff collagen matrix; therefore, despite producing higher force, CMTs constructed from higher density collagen have a lower cross-sectional stress than those constructed from lower density collagen. We also study the effect of electrical stimulation on cell alignment and force generation within CMTs and we show that the combination of electrical stimulation and auxotonic load strongly improves both the structure and the function of the CMTs. Finally, we demonstrate the suitability of our technique for high-throughput monitoring of drug-induced changes in spontaneous frequency or contractility in CMTs as well as high-speed imaging of calcium dynamics using fluorescent dyes. Together, these results highlight the potential for this approach to quantitatively demonstrate the impact of physical parameters on the maturation, structure, and function of cardiac tissue and open the possibility to use high-throughput, low volume screening for studies on engineered myocardium.

Indexed as