Evidence map›Paper›PMID 22074292›Full record

ArticleAnalytical chemistry2011

Accelerated high-resolution differential ion mobility separations using hydrogen.

Alexandre A Shvartsburg, Richard D Smith

Abstract read
In one paragraph

Article in Analytical chemistry, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Spatial Ion Peak Compression and its Utility in Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2016
    Article
  7. To What Extent is FAIMS Beneficial in the Analysis of Proteins?Journal of the American Society for Mass Spectrometry · 2016
    Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Automated deconvolution of overlapped ion mobility profiles.Journal of the American Society for Mass Spectrometry · 2014
    Article
  13. Review
  14. Differential ion mobility separations in up to 100% helium using microchips.Journal of the American Society for Mass Spectrometry · 2014
    Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. High-definition differential ion mobility spectrometry with resolving power up to 500.Journal of the American Society for Mass Spectrometry · 2013
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Alexandre A ShvartsburgBiological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA. alexandre.shvartsburg@pnl.gov
Richard D Smith

Funding

WORKSHOP AND TRAINING ACTIVITIESP41RR018522 · NCRR · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI SMITH, RICHARD D · 2003 to 2011
$25.1M
NCRR NIH HHS P41 RR018522NCRR NIH HHS RR18522
6 · The paper itself

Abstract

The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the need for resolution of complex mixtures is virtually open-ended and many topical analyses demand yet finer separations. Also, the resolving power gains are often at the expense of speed, in particular making high-resolution FAIMS poorly compatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N(2) containing up to 90% H(2). Such compositions raise the mobilities of all ions and thus the resolving power beyond that previously feasible, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases in resolving power and ensuing peak resolution are especially significant at H(2) fractions above ~50%. Higher resolution can be exchanged for acceleration of the analyses by up to ~4 times. For more mobile species such as multiply charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H(2) should consistently improve resolution for all analytes.

Indexed as

Mass SpectrometryGasesHydrogenIonsNitrogenPeptidesGasesHydrogenIonsNitrogenPeptides

Identifiers

PMID22074292
PMCPMC3234991

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.