Evidence map›Paper›PMID 22052426›Full record

ArticleSurgical endoscopy2012

Video. Transanal specimen retrieval using the transanal endoscopic microsurgery (TEM) system in minimally invasive colon resection.

Konstantinos I Makris, Erwin Rieder, Andrew S Kastenmeier, Lee L Swanström

Abstract readVideo-Audio Media
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Konstantinos I MakrisDepartment of Surgery Minimally Invasive Surgery Program, Legacy Health System, Portland, OR, USA.
Erwin Rieder
Andrew S Kastenmeier
Lee L Swanström
Legacy Health · USOregon Clinic · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring laparoscopic colectomy, the specimen is retrieved through substantial incisions, which increase postoperative pain, wound infections, and incisional hernias. In the era of natural orifice transluminal endoscopic surgery (NOTES), incisionless transrectal approaches for colon resections have been investigated with promising results [4-6]. Transanal retrieval of the colonic specimen in laparoscopic colectomy has been described but not widely adopted, although it seems to be an appealing step towards NOTES colectomy. We have used the TEM rectoscope (Richard Wolf Medical Instruments Corporation, Vernon Hills, IL, USA) as a retrieval conduit, which facilitates transanal extraction of the specimen, and protects the rectal edge and anal sphincter during laparoscopic left colectomy. TECHNIQUE: After standard laparoscopic dissection and vascular control, the colon is divided distally, whereas the proximal colonic end is ligated to prevent fecal spillage. The TEM rectoscope is advanced through the rectal stump. The proximal colon is grasped and withdrawn through the rectoscope. The colon is stapled off proximally, and the specimen is removed transanally. An anvil is introduced into the pelvis through the rectoscope and inserted in the descending colon through a colotomy, which is subsequently sealed with an endo-loop. The rectoscope is withdrawn, and the rectal stump edge is stapled off. A circular stapler is introduced in the rectum, and end-to-end anastomosis is performed. DISCUSSION: The extraction incisions in laparoscopic colectomy increase invasiveness and compromise the "purity" of the laparoscopic approach. Retrieval of the specimen through natural orifices constitutes a stepping stone in the transition to future incisionless NOTES colectomy. These techniques have not been widely adopted because of technical difficulties and concerns regarding trauma. In our experience, transanal retrieval of the colonic specimen is hampered by friction between the specimen and the rectum, which requires countertraction to the edges of the open rectal stump. These manipulations are time consuming and increase the risk of injury, even when retrieval bags are used. The TEM rectoscope allows gentle dilation of the anus, provides stability during extraction, and protects the edges of the rectum, therefore decreasing the risk of rectal or anal canal injuries. It maintains pneumoperitoneum and eases retrieval of the specimen through the large-caliber metal conduit. Alternative options in the form of a rigid conduit would be the use of the transanal endoscopic operation device (Karl Storz, Tuttlingen, Germany), the plastic McCartney tube (Tyco Healthcare, Norwalk, CT, USA) used for transvaginal operations, or an anecdotally reported, "homemade" rectoscope from a customized polyvinyl chloride tube. Potential limitations of this technique include the increased cost of acquiring and using the TEM rectoscope, although this should not be significant if this reusable system is already available for transanal procedures. The 4 cm diameter of the TEM rectoscope can also be a limiting factor in the case of large, bulky, incompressible specimens or large colonic tumors. We have also avoided using this technique in patients with preexisting anal sphincter dysfunction and fecal incontinence, as well as in the presence of severe perianal disease (i.e., fistulae or fissures). Naturally, the open lumen in the peritoneal cavity raises concerns regarding bacterial contamination and potential tumor cell seeding in cases of cancer. Preliminary evidence on these issues comes from TEM and NOTES research without obvious signs of increased risk currently. We do not perform preoperative bowel preparation for our colectomies, but we do perform rectal enema with Betadine solution at the beginning of the procedure.

conclusionsUse of the TEM system facilitates transanal removal of the specimen and protects the anorectum during laparoscopic colectomy.

Indexed as

ColectomyHumansMicrosurgeryNatural Orifice Endoscopic SurgerySpecimen Handling

Identifiers

PMID22052426
OpenAlexW2090339206

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.