Evidence map›Paper›PMID 22047146›Full record

ArticleAnalytical chemistry2011

High resolution time-of-flight mass analysis of the entire range of intact singly-charged proteins.

Jeonghoon Lee, Huijuan Chen, Tiancheng Liu, Clifford E Berkman, Peter T A Reilly

Abstract read
In one paragraph

Article in Analytical chemistry, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. A PSMA-targeted doxorubicin small-molecule drug conjugate.Bioorganic & medicinal chemistry letters · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Digital Waveform Technology and the Next Generation of Mass Spectrometers.Journal of the American Society for Mass Spectrometry · 2018
    Article
  6. Theranostics · 2017
    Article
  7. Article
  8. Boundaries of mass resolution in native mass spectrometry.Journal of the American Society for Mass Spectrometry · 2014
    Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jeonghoon LeeWashington State University, Department of Chemistry, Pullman, Washington 99164, United States.
Huijuan Chen
Tiancheng Liu
Clifford E Berkman
Peter T A Reilly

Funding

Probe Optimization for Prostate Cancer DetectionR01CA140617 · NCI · WASHINGTON STATE UNIVERSITY · PI BERKMAN, CLIFFORD · 2010 to 2013
$1.8M
Accurate Mass Analysis of Singly-Charged Intact ProteinsR01GM088501 · NIGMS · WASHINGTON STATE UNIVERSITY · PI REILLY, PETER T. A. · 2009 to 2010
$572k
NCI NIH HHS 5R01CA140617-02NCI NIH HHS R01 CA140617NIGMS NIH HHS R01 GM088501
6 · The paper itself

Abstract

The proof of principle for high-resolution analysis of intact singly charged proteins of any size is presented. Singly charged protein ions were produced by electrospray ionization followed by surface-induced charge reduction at atmospheric pressure. The inlet and trapping system "stops" the forward momentum of the protein ions over a very broad range to be captured by the digitally produced electric fields of a large radius linear ion trap whereupon they are moved into a smaller radius linear ion trap and collected and concentrated in front of its exit end-cap electrode using digital waveform manipulation. The protein ions are then ejected on demand from the end of the small radius linear quadrupole in a tightly collimated ion beam with an instrumentally defined kinetic energy into the acceleration region of an orthogonal acceleration reflectron time-of-flight mass analyzer where their flight times were measured and detected with a Photonis BiPolar TOF detector. We present results that clearly prove that massive singly charged ions can yield high-resolution mass spectra with very low chemical noise and without loss of sensitivity with increasing mass across the entire spectrum. Analysis of noncovalently bound protein complexes was demonstrated with streptavidin-Cy5 bound with a biotinylated peptide mimic. Our results suggest proteins across the entire range can be directly quantified using our mass analysis technique. We present evidence that solvent molecules noncovalently adduct onto the proteins while yielding consistent flight time distributions. Finally, we provide a look into future that will result from the ability to rapidly measure and quantify protein distributions.

Indexed as

Spectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationAtmospheric PressureBiotinylationCarbocyaninesElectrodesIonsMolecular WeightPeptidesProteinsStreptavidinCarbocyaninescyanine dye 5IonsPeptidesProteinsStreptavidin

Identifiers

PMID22047146
PMCPMC3237766

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.