ArticleAnalytical chemistry2011
High resolution time-of-flight mass analysis of the entire range of intact singly-charged proteins.
Article in Analytical chemistry, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A PSMA-targeted doxorubicin small-molecule drug conjugate.Bioorganic & medicinal chemistry letters · 2024Article
- Repurposing of PSMA-targeted diagnostic and therapeutic agents for the detection and treatment of giant cell tumors of bone.Frontiers in oncology · 2024Article
- Highly sensitive single-molecule detection of macromolecule ion beams.Science advances · 2023Article
- In Silico Demonstration of Two-Dimensional Mass Spectrometry Using Spatially Dependent Fragmentation.Journal of the American Society for Mass Spectrometry · 2023Article
- Digital Waveform Technology and the Next Generation of Mass Spectrometers.Journal of the American Society for Mass Spectrometry · 2018Article
- Article
- Detection of large ions in time-of-flight mass spectrometry: effects of ion mass and acceleration voltage on microchannel plate detector response.Journal of the American Society for Mass Spectrometry · 2014Article
- Boundaries of mass resolution in native mass spectrometry.Journal of the American Society for Mass Spectrometry · 2014Article
- Analysis of protein isoforms: can we do it better?Proteomics · 2012Review
- Increasing the Trapping Mass Range to m/z = 10(9)-A Major Step Toward High Resolution Mass Analysis of Intact RNA, DNA and Viruses.International journal of mass spectrometry · 2012Article
- Targeting prostate cancer cells with a multivalent PSMA inhibitor-guided streptavidin conjugate.Bioorganic & medicinal chemistry letters · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The proof of principle for high-resolution analysis of intact singly charged proteins of any size is presented. Singly charged protein ions were produced by electrospray ionization followed by surface-induced charge reduction at atmospheric pressure. The inlet and trapping system "stops" the forward momentum of the protein ions over a very broad range to be captured by the digitally produced electric fields of a large radius linear ion trap whereupon they are moved into a smaller radius linear ion trap and collected and concentrated in front of its exit end-cap electrode using digital waveform manipulation. The protein ions are then ejected on demand from the end of the small radius linear quadrupole in a tightly collimated ion beam with an instrumentally defined kinetic energy into the acceleration region of an orthogonal acceleration reflectron time-of-flight mass analyzer where their flight times were measured and detected with a Photonis BiPolar TOF detector. We present results that clearly prove that massive singly charged ions can yield high-resolution mass spectra with very low chemical noise and without loss of sensitivity with increasing mass across the entire spectrum. Analysis of noncovalently bound protein complexes was demonstrated with streptavidin-Cy5 bound with a biotinylated peptide mimic. Our results suggest proteins across the entire range can be directly quantified using our mass analysis technique. We present evidence that solvent molecules noncovalently adduct onto the proteins while yielding consistent flight time distributions. Finally, we provide a look into future that will result from the ability to rapidly measure and quantify protein distributions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.