Evidence map›Paper›PMID 22040119›Full record

Trial reportBMC musculoskeletal disorders2011

Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study.

Ian F H Koblbauer, Yannick Lambrecht, Micheline L M van der Hulst, Camille Neeter, Raoul H H Engelbert, Rudolf W Poolman, Vanessa A Scholtes

Abstract readClinical TrialValidation Study
In one paragraph

Trial report in BMC musculoskeletal disorders, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 56 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
56citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

56 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Observational
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ian F H KoblbauerUniversity of Applied Sciences, Amsterdam School of Health Professions, Amsterdam, The Netherlands. i.koblbauer@gmail.com
Yannick Lambrecht
Micheline L M van der Hulst
Camille Neeter
Raoul H H Engelbert
Rudolf W Poolman
Vanessa A Scholtes

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.

methodsTo determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.

resultsIn both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.

conclusionsModified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.

Indexed as

ArthralgiaArthroplasty, Replacement, KneeFemaleHumansIsometric ContractionKnee JointMaleMiddle AgedMuscle StrengthMuscle Strength DynamometerObserver VariationOsteoarthritis, KneePreoperative CareRecovery of Function

Identifiers

PMID22040119
PMCPMC3229470

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.