ArticleElectrophoresis2011
Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials.
Article in Electrophoresis, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 26 citations in OpenAlex.
- Use of 3D printing to integrate microchip electrophoresis with amperometric detection.Analytical and bioanalytical chemistry · 2024Article
- Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.Analytical and bioanalytical chemistry · 2020Review
- Polycaprolactone-enabled sealing and carbon composite electrode integration into electrochemical microfluidics.Lab on a chip · 2019Article
- Integrating 3D Cell Culture of PC12 Cells with Microchip-Based Electrochemical Detection.Analytical methods : advancing methods and applications · 2019Article
- Continuous monitoring of adenosine and its metabolites using microdialysis coupled to microchip electrophoresis with amperometric detection.Analytical methods : advancing methods and applications · 2018Article
- Real-Time Monitoring of Cellular Bioenergetics with a Multianalyte Screen-Printed Electrode.Analytical chemistry · 2015Article
- Sheath-flow microfluidic approach for combined surface enhanced Raman scattering and electrochemical detection.Analytical chemistry · 2015Article
- A review of microdialysis coupled to microchip electrophoresis for monitoring biological events.Journal of chromatography. A · 2015Review
- Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.Analytical methods : advancing methods and applications · 2015Article
- Fabrication and Characterization of All-Polystyrene Microfluidic Devices with Integrated Electrodes and Tubing.Analytical methods : advancing methods and applications · 2015Article
- Fast and versatile fabrication of PMMA microchip electrophoretic devices by laser engraving.Electrophoresis · 2014Article
- 3D printed microfluidic devices with integrated versatile and reusable electrodes.Lab on a chip · 2014Article
- Encapsulation of Fluidic Tubing and Microelectrodes in Microfluidic Devices: Integrating Off-Chip Process and Coupling Conventional Capillary Electrophoresis with Electrochemical Detection.Analytical methods : advancing methods and applications · 2013Article
- Spectroscopic and electrochemical characterization of nanostructured optically transparent carbon electrodes.Electrophoresis · 2013Article
- Integration of a graphite/poly(methyl-methacrylate) composite electrode into a poly(methylmethacrylate) substrate for electrochemical detection in microchips.Electrophoresis · 2013Article
- Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement.Electrophoresis · 2013Article
- Advances in microfluidic materials, functions, integration, and applications.Chemical reviews · 2013Review
- Integration of multiple components in polystyrene-based microfluidic devices part I: fabrication and characterization.The Analyst · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.