ArticleRadiation measurements2011
Comparison of Continuous Wave, Spin Echo, and Rapid Scan EPR of Irradiated Fused Quartz.
Article in Radiation measurements, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Field-domain rapid-scan EPR at 240GHz for studies of protein functional dynamics at room temperature.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024Article
- Cyclic Disulfide-Bridged Dinitroxide Biradical for Measuring Thiol Redox Status by Electron Paramagnetic Resonance.The journal of physical chemistry. B · 2023Article
- Rapid-scan electron paramagnetic resonance using an EPR-on-a-Chip sensor.Magnetic resonance (Gottingen, Germany) · 2021Article
- EPR Everywhere.Applied magnetic resonance · 2021Review
- Nonresonant Transmission Line Probe for Sensitive Interferometric Electron Spin Resonance Detection.Analytical chemistry · 2019Article
- Modular imaging system: Rapid scan EPR at 800 MHz.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Review
- Exchange Phenomena in the Electron Paramagnetic Resonance Spectra of the Nitroxyl and Trityl Radicals: Multifunctional Spectroscopy and Imaging of Local Chemical Microenvironment.Analytical chemistry · 2017Review
- Concept of Phase Cycling in Pulsed Magnetic Resonance Using Sinusoidal Magnetic Field Modulation.Zeitschrift fur physikalische Chemie (Frankfurt am Main, Germany) · 2017Article
- Accelerated dynamic EPR imaging using fast acquisition and compressive recovery.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2016Article
- Rapid scan electron paramagnetic resonance at 1.0 GHz of defect centers in γ-irradiated organic solids.Radiation measurements · 2016Article
- Imaging disulfide dinitroxides at 250 MHz to monitor thiol redox status.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015Article
- X-Band Rapid-Scan Electron Paramagnetic Resonance of Radiation-Induced Defects in Tooth Enamel.Radiation research · 2015Article
- Improved sensitivity for imaging spin trapped hydroxyl radical at 250 MHz.Chemphyschem : a European journal of chemical physics and physical chemistry · 2015Article
- Rapid-Scan EPR of Nitroxide Spin Labels and Semiquinones.Methods in enzymology · 2015Article
- Rapid-scan EPR of immobilized nitroxides.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2014Article
- Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals.Biophysical journal · 2013Article
- Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The E' defect in irradiated fused quartz has spin lattice relaxation times (T(1)) about 100 to 300 μs and spin-spin relaxation times (T(2)) up to about 200 μs, depending on the concentration of defects and other species in the sample. These long relaxation times make it difficult to record an unsaturated continuous wave (CW) electron paramagnetic resonance (EPR) signal that is free of passage effects. Signals measured at X-band (~9.5 GHz) by three EPR methods: conventional slow-scan field modulated EPR, rapid scan EPR, and pulsed EPR, were compared. To acquire spectra with comparable signal-to-noise, both pulsed and rapid scan EPR require less time than conventional CW EPR. Rapid scan spectroscopy does not require the high power amplifiers that are needed for pulsed EPR. The pulsed spectra, and rapid scan spectra obtained by deconvolution of the experimental data, are free of passage effects.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.