Evidence map›Paper›PMID 21972076›Full record

ArticleJournal of magnetic resonance imaging : JMRI2011

Determination of cranio-spinal canal compliance distribution by MRI: Methodology and early application in idiopathic intracranial hypertension.

Rong-Wen Tain, Ahmet M Bagci, Byron L Lam, Evelyn M Sklar, Birgit Ertl-Wagner, Noam Alperin

Open access · bronzeAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 65 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Clinical and prognostic importance of craniospinal elastance and pressure volume index in pediatric pseudotumor cerebri syndrome.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2023
    Observational
  14. Article
  15. Article
  16. Article
  17. Article
  18. Non-invasive detection of intracranial pressure related to the optic nerve.Quantitative imaging in medicine and surgery · 2021
    Review
  19. Article
  20. Does the brain have mechanical compliance?Magma (New York, N.Y.) · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Rong-Wen TainDepartment of Radiology, University of Miami, Miami, Florida, USA.
Ahmet M Bagci
Byron L Lam
Evelyn M Sklar
Birgit Ertl-Wagner
Noam Alperin
University of Miami · US

Funding

Development and Early Clinical Evaluation of Noninvasive MRI Measurement of ICPR01NS052122 · NINDS · UNIVERSITY OF MIAMI SCHOOL OF MEDICINE · PI ALPERIN, NOAM · 2006 to 2011
$1.5M
NINDS NIH HHS R01 NS052122NINDS NIH HHS R01 NS052122 NA
6 · The paper itself

Abstract

purposeTo develop a method for derivation of the cranial-spinal compliance distribution, assess its reliability, and apply to obese female patients with a diagnosis of idiopathic intracranial hypertension (IIH). MATERIALS AND

methodsPhase contrast-based measurements of blood and cerebrospinal fluid (CSF) flows to, from, and between the cranial and spinal canal compartments were used with lumped-parameter modeling to estimate systolic volume and pressure changes from which cranial and spinal compliance indices are obtained. The proposed MRI indices are analogous to pressure volume indices (PVI) currently being measured invasively with infusion-based techniques. The consistency of the proposed method was assessed using MRI data from seven aged healthy subjects. Measurement reproducibility was assessed using five repeated MR scans from one subject. The method was then applied to compare spinal canal compliance contribution in seven IIH patients and six matched healthy controls.

resultsIn the healthy subjects, as expected, spinal canal contribution was consistently larger than the cranial contribution (average value of 69%). Measurement variability was 8%. In IIH, the spinal canal contribution is significantly smaller than normal controls (60 versus 78%, P < 0.03).

conclusionAn MRI-based method for derivation of compliance indices analogous to PVI has been implemented and applied to healthy subjects. The application of the method to obese IIH patients suggests a spinal canal involvement in the pathophysiology of IIH.

Indexed as

AdultAgedCerebrospinal FluidComplianceFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedModels, TheoreticalPseudotumor CerebriRegional Blood FlowReproducibility of ResultsSkullSpinal Canal

Identifiers

PMID21972076
PMCPMC3221868
OpenAlexW1967298662

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.