ArticleClinical research in cardiology : official journal of the German Cardiac Society2012
Remote monitoring of heart failure patients using implantable cardiac pacing devices and external sensors: results of the Insight-HF study.
Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 11 citations in OpenAlex.
- Effects of chronic carotid baroreceptor activation on arterial stiffness in severe heart failure.Clinical research in cardiology : official journal of the German Cardiac Society · 2016Trial
- Adherence to eHealth Interventions Among Patients With Heart Failure: Scoping Review.JMIR mHealth and uHealth · 2025Article
- Physical Activity in Patients With Heart Failure During and After COVID-19 Lockdown: Single-Center Observational Retrospective Study.JMIR cardio · 2022Article
- Influential Factors in Remote Monitoring of Heart Failure Patients: A Review of the Literature and Direction for Future Research.Sensors (Basel, Switzerland) · 2021Review
- Heart rate in patients with reduced ejection fraction: relationship between single time point measurement and mean heart rate on prolonged implantable cardioverter defibrillator monitoring.BMC cardiovascular disorders · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThe rapidly increasing prevalence and poor outcome of congestive heart failure have stimulated the development of different telemonitoring technologies. In this study, we monitored remotely self-measured body weight and blood pressure, in parallel with the data automatically transmitted by implantable cardioverter-defibrillators. The primary aim of this study was to evaluate the correlation between different parameters screened by these two telemonitoring systems. METHODS AND
resultsThirty-two patients in NYHA class III heart failure were followed for 164 ± 48 days after cardioverter-defibrillator implantation. In 29 patients, mean heart rate (MHR), resting heart rate (RHR), and patient activity (determined by implanted devices), weight and blood pressure measurements were received on 85% of all days when remote data transmissions were expected. Based on approximately 4,000 daily pairs of measurements pooled for all patients, weight inversely correlated with activity and with the difference between MHR and RHR. By contrast, blood pressure did not correlate with weight, activity, or the difference between MHR and RHR, but it correlated with MHR and RHR individually.
conclusionBody weight, patient activity, and the difference between MHR and RHR are mutually correlated and may reasonably contribute to an algorithm for predicting heart failure deterioration. Blood pressure appears to offer no additional value. As both genesis and symptoms of heart failure exacerbation are non-uniform and complex, the telemonitoring concepts for heart failure patients should employ continuous monitoring of multiple diagnostic parameters, rather than rely on a single parameter. Provided that patient compliance is strictly supervised, reliable data flow from sensors requiring patient involvement is possible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.