Evidence map›Paper›PMID 21968791›Full record

ArticleIEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society2011

Preliminary evaluation of a powered lower limb orthosis to aid walking in paraplegic individuals.

Ryan J Farris, Hugo A Quintero, Michael Goldfarb

Abstract readEvaluation Study
In one paragraph

Article in IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 50 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
50citing papers in PubMed, 2 pooled it
14.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

50 citing papers in PubMed, 2 syntheses or guidelines pooled it, 336 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Trial
  6. Towards the use of a lower limb exoskeleton for locomotion assistance in individuals with neuromuscular locomotor deficits.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2012
    Trial
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. A Tube-based Model Predictive Control Method to Regulate a Knee Joint with Functional Electrical Stimulation and Electric Motor Assist.IEEE transactions on control systems technology : a publication of the IEEE Control Systems Society · 2021
    Article
  17. Review of control strategies for lower-limb exoskeletons to assist gait.Journal of neuroengineering and rehabilitation · 2021
    Review
  18. Review
  19. Design and Validation of a Powered Knee-Ankle Prosthesis with High-Torque, Low-Impedance Actuators.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2020
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Ryan J FarrisVanderbilt University, Nashville, TN 37235, USA. ryan.farris@vanderbilt.edu
Hugo A Quintero
Michael Goldfarb
Vanderbilt University · USVanderbilt Health · US

Funding

A Joint-Coupled Controlled-Brake Orthosis System for Hybrid FES Gait RestorationR01HD059832 · NICHD · VANDERBILT UNIVERSITY · PI GOLDFARB, MICHAEL · 2009 to 2013
$1.9M
NICHD NIH HHS 1R01HD059832-01A1NICHD NIH HHS R01 HD059832
6 · The paper itself

Abstract

This paper describes a powered lower-limb orthosis that is intended to provide gait assistance to spinal cord injured (SCI) individuals by providing assistive torques at both hip and knee joints. The orthosis has a mass of 12 kg and is capable of providing maximum joint torques of 40 Nm with hip and knee joint ranges of motion from 105° flexion to 30° extension and 105° flexion to 10° hyperextension, respectively. A custom distributed embedded system controls the orthosis with power being provided by a lithium polymer battery which provides power for one hour of continuous walking. In order to demonstrate the ability of the orthosis to assist walking, the orthosis was experimentally implemented on a paraplegic subject with a T10 complete injury. Data collected during walking indicates a high degree of step-to-step repeatability of hip and knee trajectories (as enforced by the orthosis) and an average walking speed of 0.8 km/hr. The electrical power required at each hip and knee joint during gait was approximately 25 and 27 W, respectively, contributing to the 117 W overall electrical power required by the device during walking. A video of walking corresponding to the aforementioned data is included in the supplemental material.

Indexed as

Orthotic DevicesAdultBiomechanical PhenomenaElectric Power SuppliesElectronicsEquipment DesignGaitHipHumansKneeLegLower ExtremityMaleMiddle AgedNoiseParaplegia

Identifiers

PMID21968791
PMCPMC3367884
OpenAlexW2006355360

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.