Evidence map›Paper›PMID 21961885›Full record

ArticleAnalytical chemistry2011

Immobilization of a human epidermal growth factor receptor 2 mimotope-derived synthetic peptide on Au and its potential application for detection of herceptin in human serum by quartz crystal microbalance.

Yuqin Shang, Pankaj R Singh, Mohammad M Chisti, Ray Mernaugh, Xiangqun Zeng

Abstract read
In one paragraph

Article in Analytical chemistry, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 29 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Recombinant antibodies and their use in biosensors.Analytical and bioanalytical chemistry · 2012
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Yuqin ShangChemistry Department, Oakland University, Rochester, Michigan 48309, USA.
Pankaj R Singh
Mohammad M Chisti
Ray Mernaugh
Xiangqun Zeng
Oakland University · USBeaumont Hospital, Royal Oak · USVanderbilt University · US

Funding

ScFv Piezoimmunosensor Detection of Therapeutic Antibodies in Human SerumR21EB009513 · NIBIB · OAKLAND UNIVERSITY · PI ZENG, XIANGQUN · 2010 to 2011
$420k
NIBIB NIH HHS R21EB006495NIBIB NIH HHS R21 EB009513
6 · The paper itself

Abstract

Therapeutic antibodies are antigenically similar to human antibodies and are difficult to detect in assays of human serum samples without the use of the therapeutic antibody's complementary antigen. Herein for the first time, we established a platform to detect Herceptin in solutions by using a small (<2.2 kDa), inexpensive, highly stable human epidermal growth factor receptor (HER2) mimotope-derived synthetic peptide immobilized on the surface of a Au quartz electrode. We used the HER2 mimotope as a substitute for the HER2 receptor protein in piezoimmunosensor or quartz crystal microbalance (QCM) assays to detect Herceptin in human serum. We demonstrated that assay sensitivity was dependent upon the amino acids used to tether and link the peptide to the sensor surface and the buffers used to carry out the assays. The detection limit of the piezoimmunosensor assay was 0.038 nM with a linear operating range of 0.038-0.859 nM. Little nonspecific binding to other therapeutic antibodies (Avastin and Rituxan) was observed. Levels of Herceptin in serum samples obtained from treated patients, as ascertained using the synthetic peptide-based QCM assay, were typical for those treated with Herceptin. The findings of this study are significant in that low-cost synthetic peptides could be used in a QCM assay, in lieu of native or recombinant antigens or capture antibodies, to rapidly detect a therapeutic antibody in human serum. The results suggested that a synthetic peptide bearing a particular functional sequence could be applied for developing a new generation of affinity-based immunosensors to detect a broad range of clinical biomarkers.

Indexed as

Quartz Crystal Microbalance TechniquesAntibodies, Monoclonal, HumanizedElectrodesErb-b2 Receptor Tyrosine KinasesFemaleGoldHumansImmobilized ProteinsImmunoassayPeptidesProtein BindingTrastuzumabAntibodies, Monoclonal, HumanizedERBB2 protein, humanErb-b2 Receptor Tyrosine KinasesGoldImmobilized ProteinsPeptidesTrastuzumab

Identifiers

PMID21961885
PMCPMC3234294
OpenAlexW69131926

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.