ArticleInvestigative ophthalmology & visual science2011

Noninvasive intratissue refractive index shaping (IRIS) of the cornea with blue femtosecond laser light.

Lisen Xu, Wayne H Knox, Margaret DeMagistris, Nadan Wang, Krystel R Huxlin

Registry-linked trialOpen access · bronzeAbstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03653715 (Clinical Performance Study of Clerio Single Vision and Bifocal Contact Lens Designs Immediately Following Insertion), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.1field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03653715 nacompletednot on this mapstarted 2018, after this paper: background citation

Clinical Performance Study of Clerio Single Vision and Bifocal Contact Lens Designs Immediately Following Insertion

TypeinterventionalSponsorClerio Vision, Inc.Ran2018 to 2018Enrolled30ConditionsPresbyopiaArmsClerio Vision LIRIC-modified Bifocal Contact Lens, Johnson & Johnson 1-Day Acuvue Moist Multifocal Contact Lens, Johnson & Johnson 1-Day Acuvue Moist Contact Lens, Clerio Vision Single Vision Contact Lens
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. First demonstration of ocular refractive change using blue-IRIS in live cats.Investigative ophthalmology & visual science · 2014
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lisen XuThe Institute of Optics, University of Rochester, Rochester, New York, USA.
Wayne H Knox
Margaret DeMagistris
Nadan Wang
Krystel R Huxlin
Instituto de Óptica "Daza de Valdés" · ES

Funding

VISUAL SCIENCE RESEARCH CTR SUPPORTP30EY001319 · NEI · UNIVERSITY OF ROCHESTER · PI MICHELE RUCCI · 1985 to 2026
$17.5M
The role of PPAR{gamma} ligands in corneal wound healing and opticsR01EY015836 · NEI · UNIVERSITY OF ROCHESTER · PI HUXLIN, KRYSTEL R · 2004 to 2023
$7.1M
NEI NIH HHS 08P0EY01319FNEI NIH HHS P30 EY001319NEI NIH HHS R01 EY015836
6 · The paper itself

Abstract

purposeTo test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses.

methodsFresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death.

resultsScanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns.

conclusionsBlue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique.

Indexed as

AnimalsApoptosisCatsCell SurvivalCorneaFeasibility StudiesIn Situ Nick-End LabelingLaser TherapyRefractive Surgical Procedures

Identifiers

PMID21931133
PMCPMC3208024
OpenAlexW1980522226

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.