ArticleJournal of biomechanics2011
The effects of pad geometry and material properties on the biomechanical effectiveness of 26 commercially available hip protectors.
Article in Journal of biomechanics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 67 citations in OpenAlex.
- Test systems for the biomechanical evaluation of hip protectors: a systematic review.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2020Pooled it
- Vitamin D and hip protectors in osteosarcopenia: a combined hip fracture preventing approach.Reviews in endocrine & metabolic disorders · 2025Review
- Estimating hip impact velocity and acceleration from video-captured falls using a pose estimation algorithm.Scientific reports · 2025Article
- Proposal of the Implementation Theory Selection Model and exemplar application in fall injury prevention.PloS one · 2024Article
- Optimization of the Impact Attenuation Capability of Three-Dimensional Printed Hip Protector Produced by Fused Deposition Modeling Using Response Surface Methodology.3D printing and additive manufacturing · 2023Article
- The Influence of Fall Direction and Hip Protector on Fracture Risk: FE Model Predictions Driven by Experimental Data.Annals of biomedical engineering · 2022Article
- The Role of Fall Biomechanics in the Cause and Prevention of Bone Fractures in Older Adults.Current osteoporosis reports · 2021Review
- Article
- Development and Evaluation of Fall Impact Protection Pads Using Additive Manufacturing.Materials (Basel, Switzerland) · 2019Article
- Biomechanical testing of hip protectors following the Canadian Standards Association express document.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2019Article
- Evaluation of Inertial Sensor-Based Pre-Impact Fall Detection Algorithms Using Public Dataset.Sensors (Basel, Switzerland) · 2019Article
- Development of a stick-on hip protector: A multiple methods study to improve hip protector design for older adults in the acute care environment.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
Wearable hip protectors (padded garments) represent a promising strategy to decrease impact force and hip fracture risk during falls, and a wide range of products are currently marketed. However, little is known about how design features of hip protectors influence biomechanical effectiveness. We used a mechanical test system (simulating sideways falls) to measure the attenuation in femoral neck force provided by 26 commercially available hip protectors at three impact velocities (2, 3, and 4m/s). We also used a materials testing machine to characterize the force-deflection properties of each device. Regression analyses were performed to determine which geometric (e.g., height, width, thickness, volume) and force-deflection properties were associated with force attenuation. At an impact velocity of 3m/s, the force attenuation provided by the various hip protectors ranged between 2.5% and 40%. Hip protectors with lower stiffness (measured at 500N) provided greater force attenuation at all velocities. Protectors that absorbed more energy demonstrated greater force attenuation at the higher impact velocities (3 and 4m/s conditions), while protectors that did not directly contact (but instead bridged) the skin overlying the greater trochanter attenuated more force at velocities of 2 and 3m/s. At these lower velocities, the force attenuation provided by protectors that contacted the skin overlying the greater trochanter increased with increasing pad width, thickness, and energy dissipation. By providing a comparison of the protective value of a large range of existing hip protectors, these results can help to guide consumers and researchers in selecting hip protectors, and in interpreting the results of previous clinical trials. Furthermore, by determining geometric and material parameters that influence biomechanical performance, our results should assist manufacturers in designing devices that offer improved performance and clinical effectiveness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials