Evidence map›Paper›PMID 21895327›Full record

ArticleJournal of biomedical optics2011

First-in-human pilot study of a spatial frequency domain oxygenation imaging system.

Sylvain Gioux, Amaan Mazhar, Bernard T Lee, Samuel J Lin, Adam M Tobias, David J Cuccia, Alan Stockdale, Rafiou Oketokoun, Yoshitomo Ashitate, Edward Kelly and 6 more

Open access · bronzeAbstract read
In one paragraph

Article in Journal of biomedical optics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 86 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
86citing papers in PubMed, 1 pooled it
6.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

86 citing papers in PubMed, 1 synthesis or guideline pooled it, 163 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. [An optical parameter imaging system with profile information fusion].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2022
    Article
  19. Article
  20. Article

26 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 5 institutions in 2 countries.

Sylvain GiouxBeth Israel Deaconess Medical Center, Division of Hematology∕Oncology, Department of Medicine, Boston, Massachusetts 02215, USA.
Amaan Mazhar
Bernard T Lee
Samuel J Lin
Adam M Tobias
David J Cuccia
Alan Stockdale
Rafiou Oketokoun
Yoshitomo Ashitate
Edward Kelly
Maxwell Weinmann
Nicholas J Durr
Lorissa A Moffitt
Anthony J Durkin
Bruce J Tromberg
John V Frangioni
Beth Israel Deaconess Medical Center · USBrigham and Women's Hospital · USUniversity of California, Irvine · USBeckman Laser Institute and Medical Clinic · USModulim (United States) · US

Funding

WOUND MIGRATION FORCE MONITORINGP41RR001192 · NCRR · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHOI, BERNARD · 1985 to 2011
$14.2M
Intraoperative Near-Infrared Fluorescence ImagingR01CA115296 · NCI · CURADEL, LLC · PI FRANGIONI, JOHN V · 2005 to 2014
$13.9M
Real-Time Flap Viability Monitoring during Facial Transplantation using SFDIR01DE022820 · NIDCR · CURADEL, LLC · PI FRANGIONI, JOHN V, LEE, BERNARD TRAVIS · 2013 to 2017
$3.0M
Spatially Modulated Near-Infrared Light for Image-Guided Cancer SurgeryR21CA129758 · NCI · BETH ISRAEL DEACONESS MEDICAL CENTER · PI FRANGIONI, JOHN V · 2007 to 2009
$1.1M
NCI NIH HHS R01 CA115296NCI NIH HHS R01-CA-115296NCI NIH HHS R21 CA129758NCI NIH HHS R21-CA-129758NCRR NIH HHS P41 RR001192NCRR NIH HHS P41-RR01192NIDCR NIH HHS R01 DE022820
6 · The paper itself

Abstract

Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.

Indexed as

AnimalsEquipment DesignFemaleGastrointestinal TractHemoglobinsHumansImage Processing, Computer-AssistedLiverMammaplastyOximetryOxyhemoglobinsPilot ProjectsReproducibility of ResultsSpectroscopy, Near-InfraredSurgery, Computer-AssistedSurgical FlapsdeoxyhemoglobinHemoglobinsOxyhemoglobins

Identifiers

PMID21895327
PMCPMC3182084
OpenAlexW2047084786

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked