ArticleJournal of diabetes science and technology2011
Accuracy of the CONTOUR® blood glucose monitoring system.
Article in Journal of diabetes science and technology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Artificial intelligence-supported diabetic retinopathy screening in Tanzania: rationale and design of a randomised controlled trial.BMJ open · 2024Article
- Accuracy and User Performance of a New Blood Glucose Monitoring System.Journal of diabetes science and technology · 2021Article
- Blood-glucose levels in newborn piglets and the associations between blood-glucose levels, intrauterine growth restriction and pre-weaning mortality.Porcine health management · 2019Article
- Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals.PloS one · 2015Article
- Validity and Reliability of a Glucometer Against Industry Reference Standards.Journal of diabetes science and technology · 2014Article
- Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems.Journal of diabetes science and technology · 2013Article
- System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.Journal of diabetes science and technology · 2012Article
- Preanalytic and analytic accuracy: toward more realistic and meaningful self-monitoring of blood glucose submissions for regulatory approval.Journal of diabetes science and technology · 2011Article
Corrections and comments
- Commented on by
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe aim of the study was to assess the accuracy of the CONTOUR® blood glucose monitoring system (BGMS) according to the International Organization for Standardization's International Standard 15197 (ISO 15197:2003) guidelines and to more stringent criteria.
methodFinger stick blood samples from 105 subjects with diabetes (25 with type 1, 77 with type 2, and 3 with type unknown) were tested using the CONTOUR BGMS and YSI glucose analyzer.
results99.3% of results were within ISO 15197:2003 criteria (±15 mg/dl of YSI results at glucose concentrations <75 mg/dl and ±20% at glucose concentrations ≥75 mg/dl). Additionally, 96.7% of results were accurate according to more stringent criteria (±15 mg/dl of YSI results for glucose concentrations <100 mg/dl and ±15% for glucose concentrations ≥100 mg/dl). Error grid analysis showed that 99.3% and 0.7% of results were within zones A and B, respectively.
conclusionThe CONTOUR BGMS exceeded both the minimum acceptable accuracy based on ISO 15197:2003 and the more stringent accuracy criteria.
Indexed as