ArticleMedical physics2011
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.
Article in Medical physics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 32 citations in OpenAlex.
- X-ray scintillator lens-coupled with CMOS camera for pre-clinical cardiac vascular imaging-A feasibility study.PloS one · 2022Article
- High-Definition Zoom Mode: A High Resolution X-ray Microscope for Neurointerventional Treatment Procedures.Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2019Article
- High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study.AJNR. American journal of neuroradiology · 2019Article
- A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies.Proceedings of SPIE--the International Society for Optical Engineering · 2018Article
- Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).Proceedings of SPIE--the International Society for Optical Engineering · 2016Article
- Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison.Journal of neurointerventional surgery · 2015Article
- A novel Region of Interest (ROI) imaging technique for biplane imaging in interventional suites: high-resolution small field-of-view imaging in the frontal plane and dose-reduced, large field-of-view standard-resolution imaging in the lateral plane.Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Detector system comparison using relative CNR for specific imaging tasks related to neuro-endovascular image-guided interventions (neuro-EIGIs).Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Relative object detectability (ROD): a new metric for comparing x-ray image detector performance for a specified object of interest.Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Workflow for the use of a high-resolution image detector in endovascular interventional procedures.Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Theoretical performance analysis for CMOS based high resolution detectors.Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.Medical physics · 2013Article
- Dose Reduction Technique Using a Combination of a Region of Interest (ROI) Material X-Ray Attenuator and Spatially Different Temporal Filtering for Fluoroscopic Interventions.Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF).Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
Corrections and comments
- Erratum issued
- Erratum issued
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
purposeThe increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.
methodA microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 microm thick CsI(T1) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography.
resultsThe linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually.
conclusionsThe linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).