Evidence map›Paper›PMID 21853058›Full record

Trial reportPloS one2011

The impact of utilizing different optical coherence tomography devices for clinical purposes and in multiple sclerosis trials.

Christina V Warner, Stephanie B Syc, Aleksandra M Stankiewicz, Girish Hiremath, Sheena K Farrell, Ciprian M Crainiceanu, Amy Conger, Teresa C Frohman, Esther R Bisker, Laura J Balcer and 3 more

Abstract readClinical Trial
In one paragraph

Trial report in PloS one, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Guideline
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Observational
  15. Article
  16. Article
  17. Retinal measurements predict 10-year disability in multiple sclerosis.Annals of clinical and translational neurology · 2019
    Article
  18. Evolution of Visual Outcomes in Clinical Trials for Multiple Sclerosis Disease-Modifying Therapies.Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2018
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Christina V WarnerDepartment of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States of America.
Stephanie B Syc
Aleksandra M Stankiewicz
Girish Hiremath
Sheena K Farrell
Ciprian M Crainiceanu
Amy Conger
Teresa C Frohman
Esther R Bisker
Laura J Balcer
Elliot M Frohman
Peter A Calabresi
Shiv Saidha

Funding

Novel Clinical and Ocular Imaging Outcomes with Long-Term Follow-Up in MSR01EY019473 · NEI · UNIVERSITY OF PENNSYLVANIA · PI BALCER, LAURA · 2009 to 2010
$1.3M
Longitudinal Assessment of Visual Function in MSR01EY014993 · NEI · UNIVERSITY OF PENNSYLVANIA · PI BALCER, LAURA · 2003 to 2007
$891k
NEI NIH HHS R01 EY 014993NEI NIH HHS R01 EY014993NEI NIH HHS R01 EY 019473NEI NIH HHS R01 EY019473
6 · The paper itself

Abstract

Optical coherence tomography (OCT) derived retinal measures, particularly peri-papillary retinal nerve fiber layer (RNFL) thickness, have been proposed as outcome measures in remyelinating and neuroprotective trials in multiple sclerosis (MS). With increasing utilization of multiple centers to improve power, elucidation of the impact of different OCT technologies is crucial to the design and interpretation of such studies. In this study, we assessed relation and agreement between RNFL thickness and total macular volume (in MS and healthy controls) derived from three commonly used OCT devices: Stratus time-domain OCT, and Cirrus HD-OCT and Spectralis, two spectral-domain (SD) OCT devices. OCT was performed on both Cirrus HD-OCT and Stratus in 229 participants and on both Cirrus HD-OCT and Spectralis in a separate cohort of 102 participants. Pearson correlation and Bland-Altman analyses were used to assess correlation and agreement between devices. All OCT retinal measures correlated highly between devices. The mean RNFL thickness was 7.4 µm lower on Cirrus HD-OCT than Stratus, indicating overall poor agreement for this measurement between these machines. Further, the limits of agreement (LOA) between Cirrus HD-OCT and Stratus were wide (-4.1 to 18.9 µm), indicating poor agreement at an individual subject level. The mean RNFL thickness was 1.94 µm (LOA: -5.74 to 9.62 µm) higher on Spectralis compared to Cirrus HD-OCT, indicating excellent agreement for this measurement across this cohort. Although these data indicate that these three devices agree poorly at an individual subject level (evidenced by wide LOA in both study cohorts) precluding their co-utilization in everyday practice, the small difference for mean measurements between Cirrus HD-OCT and Spectralis indicate pooled results from these two SD-devices could be used as outcome measures in clinical trials, provided patients are scanned on the same machine throughout the trial, similar to the utilization of multiple different MRI platforms in MS clinical trials.

Indexed as

AdultFemaleHumansMacula LuteaMaleMultiple SclerosisNerve FibersRetinaTomography, Optical Coherence

Identifiers

PMID21853058
PMCPMC3154907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.