ArticleLab on a chip2011
An integrated microfluidic device for two-dimensional combinatorial dilution.
Article in Lab on a chip, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 52 citations in OpenAlex.
- A high-throughput flowless microfluidic single and multi-solute concentration gradient generator: Design and parametric study.Biomicrofluidics · 2024Article
- A Hybrid Lab-on-a-Chip Injector System for Autonomous Carbofuran Screening.Sensors (Basel, Switzerland) · 2019Article
- Rapid generation of chemical combinations on a magnetic digital microfluidic array.RSC advances · 2019Article
- Single-Layered Microfluidic Network-Based Combinatorial Dilution for Standard Simplex Lattice Design.Micromachines · 2018Article
- Generating 2-dimensional concentration gradients of biomolecules using a simple microfluidic design.Biomicrofluidics · 2017Article
- Design of a hybrid advective-diffusive microfluidic system with ellipsometric detection for studying adsorption.Biomicrofluidics · 2016Article
- Microfluidics-based 3D cell culture models: Utility in novel drug discovery and delivery research.Bioengineering & translational medicine · 2016Review
- TISSUE ENGINEERING PERFUSABLE CANCER MODELS.Current opinion in chemical engineering · 2014Article
- Generation of a chemical gradient across an array of 256 cell cultures in a single chip.The Analyst · 2013Article
- Single-molecule measurements of transient biomolecular complexes through microfluidic dilution.Analytical chemistry · 2013Article
- Microfluidic devices for cell cultivation and proliferation.Biomicrofluidics · 2013Review
- A programmable microfluidic cell array for combinatorial drug screening.Lab on a chip · 2012Article
- Biomimetic tissues on a chip for drug discovery.Drug discovery today · 2012Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
Abstract
High-throughput preparation of multi-component solutions is an integral process in biology, chemistry and materials science for screening, diagnostics and analysis. Compact microfluidic systems enable such processing with low reagent volumes and rapid testing. Here we present a microfluidic device that incorporates two gradient generators, a tree-like generator and a new microfluidic active injection system, interfaced by intermediate solution reservoirs to generate diluted combinations of input solutions within an 8 × 8 or 10 × 10 array of isolated test chambers. Three input solutions were fed into the device, two to the tree-like gradient generator and one to pre-fill the test chamber array. The relative concentrations of these three input solutions in the test chambers completely characterized device behaviour and were controlled by the number of injection cycles and the flow rate. Device behaviour was modelled by computational fluid dynamics simulations and an approximate analytic formula. The device may be used for two-dimensional (2D) combinatorial dilution by adding two solutions in different relative concentrations to each of its three inputs. By appropriate choice of the two-component input solutions, test chamber concentrations that span any triangle in 2D concentration space may be obtained. In particular, explicit inputs are given for a coarse screening of a large region in concentration space followed by a more refined screening of a smaller region, including alternate inputs that span the same concentration region but with different distributions. The ability to probe arbitrary subspaces of concentration space and to control the distribution of discrete test points within those subspaces makes the device of potential benefit for high-throughput cell biology studies and drug screening.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials