ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2011
Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in a developing community: a comparison between 2005 and 2009 versions of ACCF/ASNC appropriateness criteria.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Appropriate Use of Cardiac Stress Testing with Imaging: A Systematic Review and Meta-Analysis.PloS one · 2016Pooled it
- Prevalence of Hypertension in Cardiovascular Disease in Iran: Systematic Review and Meta-Analysis.International journal of preventive medicine · 2020Review
- The impact of combined cardiopulmonary exercise testing and SPECT myocardial perfusion imaging on downstream evaluation and management.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Significance of inferior wall ischemia in non-dominant right coronary artery anatomy.World journal of cardiology · 2017Article
- Budget impact of applying appropriateness criteria for myocardial perfusion scintigraphy: The perspective of a developing country.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Article
- Outcomes after inappropriate nuclear myocardial perfusion imaging: A meta-analysis.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Review
- Appropriateness and diagnostic yield of cardiac magnetic resonance imaging from a tertiary referral center in the Middle East.Cardiovascular diagnosis and therapy · 2015Article
- The value and appropriateness of positron emission tomography: an evolving tale.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2015Article
- Applicability of the Appropriate use Criteria for Myocardial Perfusion Scintigraphy.Arquivos brasileiros de cardiologia · 2014Article
- Applicability of the appropriate use criteria for SPECT myocardial perfusion imaging in Italy: preliminary results.European journal of nuclear medicine and molecular imaging · 2014Article
- Utilization patterns of single-photon emission cardiac tomography myocardial perfusion imaging studies in a rural tertiary care setting.Clinical cardiology · 2014Observational
- A multicenter evaluation of the appropriate use of single-photon emission tomography myocardial perfusion imaging in Greece.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2013Article
- Re: applicability, limitations and downstream impact of echocardiography utilization based on the Appropriateness Use Criteria for transthoracic and transesophageal echocardiography.The international journal of cardiovascular imaging · 2012Article
- Comment on Reyes et al.: Myocardial perfusion scintigraphy in Europe 2007: a survey of the European Council of Nuclear Cardiology.European journal of nuclear medicine and molecular imaging · 2012Article
- The time and place for appropriate radionuclide imaging: now and everywhere.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2011Article
Corrections and comments
- Commented on by
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionAppropriateness of referrals for myocardial perfusion imaging (MPI) in developing countries has not been extensively studied. Our study was conducted to describe the ordering practices of physicians and appropriateness of MPI referrals in Iran.
methodWe prospectively applied 2005 and 2009 versions of the Appropriateness Use Criteria published by the American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC) to 291 consecutive patients (age 55.3 ± 10.3 years) who underwent SPECT-MPI. For this purpose, we convened a panel, consisting of two academic cardiologists, one academic clinician in internal medicine, and one academic clinician in nuclear medicine. The panelists were invited for a face-to-face meeting to judge appropriateness of SPECT-MPI and independently assign a specific indication (scenario), whenever possible, for each case in accordance with ACCF/ASNC appropriateness scenarios.
resultsBased on the 2005 ACCF/ASNC criteria, SPECT-MPI studies were judged appropriate for 211 (72.5%), uncertain for 36 (12.4%), inappropriate for 32 (11.0%), and unclassifiable for 12 (4.1%) referrals. The same figures based on the 2009 version were 219 (75.3%), 15 (5.2%), 49 (16.8%), and 8 (2.7%) patients, respectively. Overall agreement between the 2005 and 2009 versions was good (κ 0.63). Lack of chest pain and age below 60 years were significant indicators increasing the likelihood of inappropriate referrals by 2.9-3.4 fold. Absence of diabetes mellitus and hypertension, a normal lipid profile, lack of a past history of myocardial infarction or cardiovascular interventions (CABGs or PCI), as well as lack of application and exercise ECG stress test as the gate keeper (keeping abnormal ETT or inability of the patient to perform exercise as the appropriate indication for SPECT-MPI referral) were significant indicators, decreasing the odds of appropriate referrals. Generally a higher percentage of referrals with inappropriate indications had normal MPI.
conclusionOur study provides an evidence for the fact that SPECT-MPI ordering practices in our developing community largely parallel the ACCF/ASNC recommendations. The implementation of appropriateness criteria is feasible in clinical settings and might provide an alternative to utilization management.
Indexed as
Identifiers
21818700What OpenQuestion holds
Registered trials