Evidence map›Paper›PMID 21808233›Full record

ArticleLaboratory investigation; a journal of technical methods and pathology2011

In vivo, label-free, three-dimensional quantitative imaging of kidney microcirculation using Doppler optical coherence tomography.

Jeremiah Wierwille, Peter M Andrews, Maristela L Onozato, James Jiang, Alex Cable, Yu Chen

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Laboratory investigation; a journal of technical methods and pathology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Three dimensional mesoscale analysis of translamellar cross-bridge morphologies in the annulus fibrosus using optical coherence tomography.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2015
    Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Jeremiah WierwilleFischell Department of Bioengineering, University of Maryland, College Park, MD, USA.
Peter M Andrews
Maristela L Onozato
James Jiang
Alex Cable
Yu Chen
Thorlabs (United States) · USUniversity of Maryland, College Park · USHarvard University · USUniversity of Washington · US

Funding

Depth-resolved Quantitative Multi-Modal Imaging for GI Cancer DetectionR21EB012215 · NIBIB · UNIV OF MARYLAND, COLLEGE PARK · PI CHEN, YU · 2011 to 2012
$411k
In Vivo Optical Imaging of Kidney Structure and FunctionR21DK088066 · NIDDK · UNIV OF MARYLAND, COLLEGE PARK · PI CHEN, YU · 2011 to 2012
$234k
NIBIB NIH HHS R21 EB012215NIBIB NIH HHS R21-EB012215NIDDK NIH HHS R21 DK088066
6 · The paper itself

Abstract

Doppler optical coherence tomography (DOCT) is a functional extension of optical coherence tomography (OCT) and is currently being employed in several clinical arenas to quantify blood flow in vivo. In this study, the objective was to investigate the feasibility of DOCT to image kidney microcirculation, specifically, glomerular blood flow. DOCT is able to capture three-dimensional (3D) data sets consisting of a series of cross-sectional images in real time, which enables label-free and non-destructive quantification of glomerular blood flow. The kidneys of adult, male Munich-Wistar rats were exposed through laparotomy procedure after being anesthetized. Following exposure of the kidney beneath the DOCT microscope, glomerular blood flow was observed. The effects of acute mannitol and angiotensin II infusion were also observed. Glomerular blood flow was quantified for the induced physiological states and compared with baseline measurements. Glomerular volume, cumulative Doppler volume, and Doppler flow range parameters were computed from 3D OCT/DOCT data sets. Glomerular size was determined from OCT, and DOCT readily revealed glomerular blood flow. After infusion of mannitol, a significant increase in blood flow was observed and quantified, and following infusion of angiontensin II, a significant decrease in blood flow was observed and quantified. Also, blood flow histograms were produced to illustrate differences in blood flow rate and blood volume among the induced physiological states. We demonstrated 3D DOCT imaging of rat kidney microcirculation in the glomerulus in vivo. Dynamic changes in blood flow were detected under altered physiological conditions demonstrating the real-time imaging capability of DOCT. This method holds promise to allow non-invasive imaging of kidney blood flow for transplant graft evaluation or monitoring of altered-renal hemodynamics related to disease progression.

Indexed as

Analysis of VarianceAngiotensin IIAnimalsImaging, Three-DimensionalKidney GlomerulusMaleMannitolMicrocirculationRatsRats, WistarTomography, Optical CoherenceAngiotensin IIMannitol

Identifiers

PMID21808233
PMCPMC3312876
OpenAlexW2069545989

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.