ArticleEvidence-based complementary and alternative medicine : eCAM2012
Temporal and spatial properties of arterial pulsation measurement using pressure sensor array.
Article in Evidence-based complementary and alternative medicine : eCAM, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed.
- Visualizing a Cold Stress-Specific Pulse Wave in Traditional Pulse Diagnosis ('Tight Pulse') Correlated with Vascular Changes in the Radial Artery Induced by a Cold Pressor Trial.Sensors (Basel, Switzerland) · 2024Article
- Article
- Increasing the sensor channels: a solution for the pressing offsets that cause the physiological parameter inaccuracy in radial artery pulse signal acquisition.Frontiers in bioengineering and biotechnology · 2024Article
- Wearable Multi-Channel Pulse Signal Acquisition System Based on Flexible MEMS Sensor Arrays with TSV Structure.Biomimetics (Basel, Switzerland) · 2023Article
- Integrated Piezoresistive Normal Force Sensors Fabricated Using Transfer Processes with Stiction Effect Temporary Handling.Micromachines · 2022Article
- Wearable multichannel pulse condition monitoring system based on flexible pressure sensor arrays.Microsystems & nanoengineering · 2022Article
- Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders.Evidence-based complementary and alternative medicine : eCAM · 2022Article
- Three-Dimensional Arterial Pulse Signal Acquisition in Time Domain Using Flexible Pressure-Sensor Dense Arrays.Micromachines · 2021Article
- The novel three-dimensional pulse images analyzed by dynamic L-cube polynomial model.Medical & biological engineering & computing · 2021Article
- A Noncontact Method for Locating Radial Artery above Radial Styloid Process in Thermal Image.Evidence-based complementary and alternative medicine : eCAM · 2020Article
- A 3D Wrist Pulse Signal Acquisition System for Width Information of Pulse Wave.Sensors (Basel, Switzerland) · 2019Article
- Fourier Series Analysis for Novel Spatiotemporal Pulse Waves: Normal, Taut, and Slippery Pulse Images.Evidence-based complementary and alternative medicine : eCAM · 2019Article
- Pulse wave response characteristics for thickness and hardness of the cover layer in pulse sensors to measure radial artery pulse.Biomedical engineering online · 2018Article
- Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry.Evidence-based complementary and alternative medicine : eCAM · 2018Article
- Article
- Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse.Sensors (Basel, Switzerland) · 2016Article
- Asserted and neglected issues linking evidence-based and Chinese medicines for cardiac rehabilitation.World journal of cardiology · 2014Review
- P(VDF-TrFE) polymer-based thin films deposited on stainless steel substrates treated using water dissociation for flexible tactile sensor development.Sensors (Basel, Switzerland) · 2013Article
- Pulse waveform analysis as a bridge between pulse examination in Chinese medicine and cardiology.Chinese journal of integrative medicine · 2013Review
- New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.Evidence-based complementary and alternative medicine : eCAM · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Conventionally, a pulse taking platform is based on a single sensor, which initiates a feasible method of quantitative pulse diagnosis. The aim of this paper is to implement a pulse taking platform with a tactile array sensor. Three-dimensional wrist pulse signals are constructed, and the length, width, ascending slope, and descending slope are defined following the surface of the wrist pulse. And the pressure waveform of the wrist pulse obtained through proposed pulse-taking platform has the same performance as the single sensor. Finally, the results of a paired samples t-test reveal that the repeatability of the proposal platform is consistent with clinical experience. On the other hand, the results of ANOVA indicate that differences exist among different pulse taking depths, and this result is consistent with clinical experience in traditional Chinese medicine pulse diagnosis (TCMPD). Hence, the proposed pulse taking platform with an array sensor is feasible for quantification in TCMPD.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.