Evidence map›Paper›PMID 21739322›Full record

ArticleClinical orthopaedics and related research2012

All-polyethylene tibial components in obese patients are associated with low failure at midterm followup.

David F Dalury, Kimberly K Tucker, Todd C Kelley

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05223777 (KINCISE™ Surgical Automated System in Total Hip Arthroplasty), which is not on this map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05223777 naunknown statusnot on this mapstarted 2021, after this paper: background citation

KINCISE™ Surgical Automated System in Total Hip Arthroplasty (THA)

TypeinterventionalSponsorUniversity of CincinnatiRan2021 to 2024Enrolled50ConditionsOsteoarthritis, HipArmsKINCISE, Traditional Handheld Mallet
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Obesity has no effect on outcomes following unicompartmental knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

David F DaluryTowson Orthopaedic Associates, LLC, Towson, MD, USA. ehenze1@jhmi.edu
Kimberly K Tucker
Todd C Kelley

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn the United States, the obese population has increased markedly over the last four decades, and this trend continues. High patient weight places additional stress on TKA components, which may lead to increased polyethylene wear, osteolysis, radiolucencies, and clinical failure. Metal-backed tibial components and all-polyethylene tibial components in the general population have comparable osteolysis and failure, but it is unclear whether these components yield similar osteolysis and failure in obese patients. QUESTIONS/PURPOSES: We therefore determined the (1) function, (2) occurrence of osteolysis, and (3) complications in a cohort of obese patients receiving all-polyethylene tibial components. PATIENTS AND

methodsBetween September 17, 1996, and December 19, 2002, we implanted all-polyethylene tibial components in 90 obese patients (125 knees); 24 patients (33 knees) died and 13 patients (17 knees) were lost to followup, leaving 53 patients (59%) with 75 knees. All surgeries were cruciate-retaining, tricompartmental TKAs. We evaluated patients with Knee Society Scores and serial radiographs. Minimum followup was 7 years (mean, 10.4 years; range, 7-14 years).

resultsAt latest followup, mean Knee Society Score was 92 points. There were five tibial radiolucencies, all less than 1 mm and characterized as nonprogressive. We observed minimal, nonprogressive osteolysis in one knee. One patient required reoperation after a traumatic event. There were no implant-related failures and no implants at risk of failure.

conclusionsAt an average 10-year followup, all-polyethylene tibial components were functioning well in this obese group. These findings confirm the effectiveness of all-polyethylene tibial components in obese patients.

Indexed as

Knee ProsthesisAgedAged, 80 and overAge FactorsArthroplasty, Replacement, KneeBody Mass IndexCohort StudiesFemaleFollow-Up StudiesHumansMaleMiddle AgedObesityOsteoarthritis, KneePolyethylenePostoperative PainPolyethylene

Identifiers

PMID21739322
PMCPMC3238008

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.