Evidence map›Paper›PMID 21730273›Full record

Trial reportJournal of clinical oncology : official journal of the American Society of Clinical Oncology2011

Variability of lung tumor measurements on repeat computed tomography scans taken within 15 minutes.

Geoffrey R Oxnard, Binsheng Zhao, Camelia S Sima, Michelle S Ginsberg, Leonard P James, Robert A Lefkowitz, Pingzhen Guo, Mark G Kris, Lawrence H Schwartz, Gregory J Riely

Abstract readClinical Trial
In one paragraph

Trial report in Journal of clinical oncology : official journal of the American Society of Clinical Oncology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 85 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
85citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

85 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Article
  7. Article
  8. Article
  9. Impact of reconstruction kernel variability on segmentation consistency in low-dose thoracic CT.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article

25 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Geoffrey R OxnardMemorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065, USA.
Binsheng Zhao
Camelia S Sima
Michelle S Ginsberg
Leonard P James
Robert A Lefkowitz
Pingzhen Guo
Mark G Kris
Lawrence H Schwartz
Gregory J Riely

Funding

Advanced Anatomic and Functional Response Assessment in Lung CancerR01CA125143 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI SCHWARTZ, LAWRENCE H · 2007 to 2011
$1.7M
NCI NIH HHS R01 CA125143NCI NIH HHS R01-CA125143
6 · The paper itself

Abstract

purposeWe use changes in tumor measurements to assess response and progression, both in routine care and as the primary objective of clinical trials. However, the variability of computed tomography (CT) -based tumor measurement has not been comprehensively evaluated. In this study, we assess the variability of lung tumor measurement using repeat CT scans performed within 15 minutes of each other and discuss the implications of this variability in a clinical context. PATIENTS AND

methodsPatients with non-small-cell lung cancer and a target lung lesion ≥ 1 cm consented to undergo two CT scans within a period of minutes. Three experienced radiologists measured the diameter of the target lesion on the two scans in a side-by-side fashion, and differences were compared.

resultsFifty-seven percent of changes exceeded 1 mm in magnitude, and 33% of changes exceeded 2 mm. Median increase and decrease in tumor measurements were +4.3% and -4.2%, respectively, and ranged from 23% shrinkage to 31% growth. Measurement changes were within ± 10% for 84% of measurements, whereas 3% met criteria for progression according to Response Evaluation Criteria in Solid Tumors (RECIST; ≥ 20% increase). Smaller lesions had greater variability of percent measurement change (P = .005).

conclusionApparent changes in tumor diameter exceeding 1 to 2 mm are common on immediate reimaging. Increases and decreases less than 10% can be a result of the inherent variability of reimaging. Caution should be exercised in interpreting the significance of small changes in lesion size in the care of individual patients and in the interpretation of clinical trial results.

Indexed as

Carcinoma, Non-Small-Cell LungHumansLung NeoplasmsMiddle AgedNeoplasm StagingReproducibility of ResultsTomography, X-Ray Computed

Identifiers

PMID21730273
PMCPMC3157977

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.