Modulation of the foreign body reaction for implants in the subcutaneous space: microdialysis probes as localized drug delivery/sampling devices.

Xiaodun Mou, Michelle R Lennartz, Daniel J Loegering, Julie A Stenken

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Article
  3. Drug delivery strategies to control macrophages for tissue repair and regeneration.Experimental biology and medicine (Maywood, N.J.) · 2016
    Review
  4. Review
  5. Article
  6. Microdialysis sampling techniques applied to studies of the foreign body reaction.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2014
    Review
  7. Comparison of microdialysis sampling perfusion fluid components on the foreign body reaction in rat subcutaneous tissue.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2014
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xiaodun MouDepartment of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York, USA.
Michelle R Lennartz
Daniel J Loegering
Julie A Stenken

Funding

Quantitative Biocompatibility of Implanted MaterialsR01EB001441 · NIBIB · UNIVERSITY OF ARKANSAS AT FAYETTEVILLE · PI STENKEN, JULIE A · 2003 to 2010
$1.9M
NIBIB NIH HHS EB-001441
6 · The paper itself

Abstract

Modulation of the foreign body reaction is considered to be an important step toward creation of implanted sensors with reliable long-term performance. In this work, microdialysis probes were implanted into the subcutaneous space of Sprague-Dawley rats. The probe performance was evaluated by comparing collected endogenous glucose concentrations with internal standard calibration (2-deoxyglucose, antipyrine, and vitamin B12). Probes were tested until failure, which for this work was defined as loss of fluid flow. In order to determine the effect of fibrous capsule formation on probe function, monocyte chemoattractant protein-1/CC chemokine ligand 2 (MCP-1/CCL2) was delivered locally via the probe to increase capsule thickness and dexamethasone 21-phosphate was delivered to reduce capsule thickness. Probes delivering MCP-1 had a capsule that was twice the thickness (500-600 μm) of control probes (200-225 μm) and typically failed 2 days earlier than control probes. Probes delivering dexamethasone 21-phosphate had more fragile capsules and the probes typically failed 2 days later than controls. Unexpectedly, extraction efficiency and collected glucose concentrations exhibited minor differences between groups. This is an interesting result in that the foreign body capsule formation was related to the duration of probe function but did not consistently relate to probe calibration.

Indexed as

AnimalsAntipyrineBlood Glucose Self-MonitoringCalibrationChemokine CCL2DeoxyglucoseDexamethasoneDrug Delivery SystemsForeign-Body ReactionMaleMicrodialysisModels, StatisticalRatsRats, Sprague-DawleyVitamin B 12XenobioticsAntipyrineChemokine CCL2DeoxyglucoseDexamethasonedexamethasone 21-phosphateVitamin B 12Xenobiotics

Identifiers

PMID21722577
PMCPMC3192628

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.