ArticleAJR. American journal of roentgenology2011
Prospective evaluation of MR enterography as the primary imaging modality for pediatric Crohn disease assessment.
Article in AJR. American journal of roentgenology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
40 citing papers in PubMed, 2 syntheses or guidelines pooled it, 125 citations in OpenAlex.
- Diagnostic performance of magnetic resonance enterography and ultrasound in children with inflammatory bowel diseases: a diagnostic test accuracy meta-analysis.European radiology · 2022Pooled it
- Pooled it
- Clinical utility of magnetic resonance enterography for pediatric Crohn's disease: a review with illustrative cases and a focus on Japan.Japanese journal of radiology · 2026Review
- Baseline terminal ileal CT and MRI measurements are associated with imaging outcomes in pediatric Crohn's disease: a cohort study.Pediatric radiology · 2025Article
- The Importance of Magnetic Resonance Enterography in Monitoring Inflammatory Bowel Disease: A Review of Clinical Significance and Current Challenges.Diagnostics (Basel, Switzerland) · 2025Review
- Prospective characterization of intestinal MRI intravoxel incoherent motion in pediatric and young adult patients with newly diagnosed small bowel Crohn's disease.Abdominal radiology (New York) · 2024Article
- LAVA HyperSense and deep-learning reconstruction for near-isotropic (3D) enhanced magnetic resonance enterography in patients with Crohn's disease: utility in noise reduction and image quality improvement.Diagnostic and interventional radiology (Ankara, Turkey) · 2023Article
- MR-enterography: role in the assessment of suspected anastomotic recurrence of Crohn disease after ileocolic resection.La Radiologia medica · 2022Article
- Relevance of monitoring transmural disease activity in patients with Crohn's disease: current status and future perspectives.Therapeutic advances in gastroenterology · 2021Review
- Capsule Endoscopy Complements Magnetic Resonance Enterography and Endoscopy in Evaluating Small Bowel Crohn's Disease.Journal of the Canadian Association of Gastroenterology · 2020Article
- Detection of Crohn's disease with diffusion images versus contrast-enhanced images in pediatric using MR enterography with histopathological correlation.La Radiologia medica · 2019Article
- Challenges in IBD Research: Novel Technologies.Inflammatory bowel diseases · 2019Review
- Magnetic resonance enterography evaluation of Crohn disease activity and mucosal healing in young patients.Pediatric radiology · 2018Review
- Comparison of CT enterography and MR enterography imaging features of active Crohn disease in children and adolescents.Pediatric radiology · 2017Article
- Colonic inflammation in pediatric inflammatory bowel disease: detection with magnetic resonance enterography.Pediatric radiology · 2017Article
- Assessing pediatric ileocolonic Crohn's disease activity based on global MR enterography scores.European radiology · 2017Article
- Crohn's Strictures-Moving Away from the Knife.Frontiers in pediatrics · 2017Review
- Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease.Pediatric radiology · 2017Article
- CAIPIRINHA-accelerated T1w 3D-FLASH for small-bowel MR imaging in pediatric patients with Crohn's disease: assessment of image quality and diagnostic performance.World journal of pediatrics : WJP · 2016Article
- Current tecniques and new perpectives research of magnetic resonance enterography in pediatric Crohn's disease.World journal of radiology · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveThe objectives of this study were prospective evaluation of MR enterographic accuracy for detecting Crohn disease imaging features in pediatric patients, compared with a CT reference standard, as well as determination of MR enterographic accuracy for detecting active bowel inflammation and fibrosis using a histologic reference standard. SUBJECTS AND
methodsThe study group for this blinded prospective study included 21 pediatric subjects with known Crohn disease scheduled for clinical CT and histologic bowel sampling for symptomatic exacerbation. All subjects and their parents gave informed consent to also undergo MR enterography. CT and MR enterography examinations were independently reviewed by two radiologists and were scored for Crohn disease features. All bowel histology specimens were reviewed by a single pathologist for the presence of active mucosal inflammation and mural fibrosis, followed by correlation of imaging and histologic findings.
resultsAll 21 subjects underwent MR enterography and histologic sampling, 18 of whom also underwent CT. MR enterography had high sensitivity for detecting Crohn disease imaging features (e.g., bowel wall thickening, mesenteric inflammation, lymphadenopathy, fistula, and abscess) compared with CT, with individual sensitivity values ranging from 85.1% to 100%. Of a total of 53 abnormal bowel segments with correlation of MRI and histologic findings, MR enterography showed 86.7% accuracy (90.0% sensitivity and 82.6% specificity) for detecting active inflammation (p < 0.001). The accuracy of MR enterography for detecting mural fibrosis overall was 64.9%, compared with histology, but increased to 83.3% (p < 0.05) for detecting fibrosis without superimposed active inflammation.
conclusionMR enterography can substitute for CT as the first-line imaging modality in pediatric patients with Crohn disease, on the basis of its ability to detect intestinal pathologic abnormalities in both small and large bowel as well as extraintestinal disease manifestations. Additionally, MR enterography provides an accurate noninvasive assessment of Crohn disease activity and mural fibrosis and can aid in formulating treatment strategies for symptomatic patients and assessing therapy response.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.