Use of the microangiographic fluoroscope for coiling of intracranial aneurysms.
Article in Neurosurgery, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Contemporary Management of Distal Anterior Cerebral Artery Aneurysms: A Dual-Trained Neurosurgeon's Perspective.Journal of neurosciences in rural practice · 2021Article
- High-Definition Zoom Mode: A High Resolution X-ray Microscope for Neurointerventional Treatment Procedures.Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2019Article
- Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography.AJNR. American journal of neuroradiology · 2019Article
- High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study.AJNR. American journal of neuroradiology · 2019Article
- Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison.Journal of neurointerventional surgery · 2015Article
- Workflow for the use of a high-resolution image detector in endovascular interventional procedures.Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Detector system comparison using relative CNR for specific imaging tasks related to neuro-endovascular image-guided interventions (neuro-EIGIs).Proceedings of SPIE--the International Society for Optical Engineering · 2014Article
- Third nerve palsy following carotid artery dissection and posterior cerebral artery thrombectomy: Case report and review of the literature.Surgical neurology international · 2014Article
- Theoretical performance analysis for CMOS based high resolution detectors.Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.Proceedings of SPIE--the International Society for Optical Engineering · 2013Article
- Endovascular coil embolization of a very small ruptured aneurysm using a novel microangiographic technique: technical note.Journal of neurointerventional surgery · 2013Article
- Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.Medical physics · 2013Article
- New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Dose Reduction Technique Using a Combination of a Region of Interest (ROI) Material X-Ray Attenuator and Spatially Different Temporal Filtering for Fluoroscopic Interventions.Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF).Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- Dose reduction by moving a region of interest (ROI) beam attenuator to follow a moving object of interest.Proceedings of SPIE--the International Society for Optical Engineering · 2012Article
- A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.Medical physics · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundNeurointervention is an ever-evolving specialty with tools including microcatheters, microwires, and coils that allow treatment of pathological conditions in increasingly smaller intracranial arteries, requiring increasing accuracy. As endovascular tools evolve, so too should the imaging.
objectiveTo detail the use of microangiography performed with a novel fluoroscope during coiling of intracranial aneurysms in 2 separate patients and discuss the benefits and potential limitations of the technology.
methodsThe microangiographic fluoroscope (MAF) is an ultra high-resolution x-ray detector with superior resolution over a small field of view. The MAF can be incorporated into a standard angiographic C-arm system for use during endovascular procedures.
resultsThe MAF was useful for improved visualization during endovascular coiling of 2 unruptured intracranial aneurysms, without adding significant time to the procedure. No significant residual aneurysm filling was identified post-coiling, and no complications occurred.
conclusionThe MAF is a high-resolution detector developed for use in neurointerventional cases in which superior image quality over a small field of view is required. It has been used with success for coiling of 2 unruptured aneurysms at our institution. It shows promise as an important tool in improving the accuracy with which neurointerventionists can perform certain intracranial procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.