Evidence map›Paper›PMID 21694658›Full record

ArticleNeurosurgery2011

Use of the microangiographic fluoroscope for coiling of intracranial aneurysms.

Mandy J Binning, David Orion, Parham Yashar, Sharon Webb, Ciprian N Ionita, Amit Jain, Stephen Rudin, L Nelson Hopkins, Adnan H Siddiqui, Elad I Levy

Abstract readCase ReportsEvaluation Study
In one paragraph

Article in Neurosurgery, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. High-Definition Zoom Mode: A High Resolution X-ray Microscope for Neurointerventional Treatment Procedures.Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2019
    Article
  3. Article
  4. Article
  5. Article
  6. Workflow for the use of a high-resolution image detector in endovascular interventional procedures.Proceedings of SPIE--the International Society for Optical Engineering · 2014
    Article
  7. Article
  8. Article
  9. Theoretical performance analysis for CMOS based high resolution detectors.Proceedings of SPIE--the International Society for Optical Engineering · 2013
    Article
  10. Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).Proceedings of SPIE--the International Society for Optical Engineering · 2013
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Dose reduction by moving a region of interest (ROI) beam attenuator to follow a moving object of interest.Proceedings of SPIE--the International Society for Optical Engineering · 2012
    Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mandy J BinningDepartment of Neurosurgery, University at Buffalo, State University of New York, Buffalo, New York, USA.
David Orion
Parham Yashar
Sharon Webb
Ciprian N Ionita
Amit Jain
Stephen Rudin
L Nelson Hopkins
Adnan H Siddiqui
Elad I Levy

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
Radiographic guidance of new cerebral aneurysm stentR01NS043924 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2004 to 2007
$2.5M
Hemodynamic Induction of Pathologic Remodeling Leading to Intracranial AneurysmsR01NS064592 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI MENG, HUI · 2009 to 2013
$1.7M
MICRORADIOGRAPHIC IMAGER FOR NEUROVASCULAR INTERVENTIONR01NS038746 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 1999 to 2001
$793k
NIBIB NIH HHS R01 EB002873NIBIB NIH HHS R01EB002873NINDS NIH HHS 1R01NS064592-01A1NINDS NIH HHS R01 NS038746NINDS NIH HHS R01 NS043924NINDS NIH HHS R01 NS064592NINDS NIH HHS R01NS43924
6 · The paper itself

Abstract

backgroundNeurointervention is an ever-evolving specialty with tools including microcatheters, microwires, and coils that allow treatment of pathological conditions in increasingly smaller intracranial arteries, requiring increasing accuracy. As endovascular tools evolve, so too should the imaging.

objectiveTo detail the use of microangiography performed with a novel fluoroscope during coiling of intracranial aneurysms in 2 separate patients and discuss the benefits and potential limitations of the technology.

methodsThe microangiographic fluoroscope (MAF) is an ultra high-resolution x-ray detector with superior resolution over a small field of view. The MAF can be incorporated into a standard angiographic C-arm system for use during endovascular procedures.

resultsThe MAF was useful for improved visualization during endovascular coiling of 2 unruptured intracranial aneurysms, without adding significant time to the procedure. No significant residual aneurysm filling was identified post-coiling, and no complications occurred.

conclusionThe MAF is a high-resolution detector developed for use in neurointerventional cases in which superior image quality over a small field of view is required. It has been used with success for coiling of 2 unruptured aneurysms at our institution. It shows promise as an important tool in improving the accuracy with which neurointerventionists can perform certain intracranial procedures.

Indexed as

AgedBlood Vessel Prosthesis ImplantationCerebral AngiographyEmbolization, TherapeuticFemaleFluoroscopyHumansIntracranial AneurysmMiddle AgedMonitoring, IntraoperativeNeuronavigation

Identifiers

PMID21694658
PMCPMC3706633

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.