Evidence map›Paper›PMID 21667262›Full record

ArticleHernia : the journal of hernias and abdominal wall surgery2013

Use of vacuum-assisted closure in open incisional hernia repair: a novel approach to prevent seroma formation.

M López-Cano, M Armengol-Carrasco

Abstract read
PubMed Publisher
In one paragraph

Article in Hernia : the journal of hernias and abdominal wall surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 33 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Management of skin and subcutaneous tissue in complex open abdominal wall reconstruction.Hernia : the journal of hernias and abdominal wall surgery · 2018
    Review
  7. Review
  8. Article
  9. Article
  10. Early outcome of incisional hernia repair using polypropylene mesh: A preliminary report.Nigerian medical journal : journal of the Nigeria Medical Association · 2014
    Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

M López-CanoAbdominal Wall Unit, Department of Surgery, Hospital Universitari Vall d'Hebron, Passeig Vall d'Hebron 119-129, 08035, Barcelona, Spain. manulopez@vhebron.net
M Armengol-Carrasco
Vall d'Hebron Hospital Universitari · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFrequent complications in incisional hernia surgery are re-herniation, wound infection and seroma formation. The use of subatmospheric pressure dressings such as the vacuum-assisted closure (VAC) device has been shown to be an effective way to accelerate healing of various wounds. Here, we describe the application of the VAC device as a postoperative dressing to prevent seroma formation after open incisional hernia repair.

methodsThree consecutive patients (63, 65 and 60 years of age, respectively) underwent incisional hernia repair. Patient body mass index was 30.9, 26.6 and 29 kg/m(2), respectively. All hernias were complex with a defect size greater than 10 cm and were repaired using the onlay technique. After suture skin closure the incision was covered with a thin VAC sponge (KCI, San Antonio, TX) that was set at -125 mm Hg and left in place for 5 days before removal.

resultsAn abdominal CT scan performed before discharge from the hospital did not show seroma formation. Physical examination 3 months after surgery was normal with no evidence of seroma (abdominal bulge and/or fluid wave).

conclusionsThis successful preliminary experience in three patients encourages the use of the VAC system in incisional hernia repair, particularly in selected patients with risk factors for seroma formation (e.g., large defects, obesity, patient comorbidities, nutritional status, number of prior abdominal incisions, etc.). Therefore, prevention of seroma formation after incisional hernia repair may be added as a novel application of the VAC device.

Indexed as

Abdominal Wound Closure TechniquesNegative-Pressure Wound TherapyAgedFemaleHernia, AbdominalHerniorrhaphyHumansMaleMiddle AgedSeroma

Identifiers

PMID21667262
OpenAlexW2044394972

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked