ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2011

Rapid frequency scan EPR.

Mark Tseitlin, George A Rinard, Richard W Quine, Sandra S Eaton, Gareth R Eaton

Open access · greenAbstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.6field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 40 citations in OpenAlex.

  1. Review
  2. Article
  3. Have We Been Teaching Continuous Wave EPR Correctly?Journal of chemical education · 2025
    Article
  4. Article
  5. Article
  6. EPR Everywhere.Applied magnetic resonance · 2021
    Review
  7. Article
  8. Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Review
  9. Article
  10. Article
  11. Article
  12. Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2011
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mark TseitlinDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80208, USA.
George A Rinard
Richard W Quine
Sandra S Eaton
Gareth R Eaton
University of Denver · US

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Radiation Biology of EPR Oxygen ImagesR01CA098575 · NCI · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2022
$4.5M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR01EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2002 to 2011
$4.0M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR56EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2007 to 2007
$494k
NCI NIH HHS R01 CA098575NIBIB NIH HHS EB000557NIBIB NIH HHS P41 EB002034NIBIB NIH HHS R01 EB000557NIBIB NIH HHS R56 EB000557
6 · The paper itself

Abstract

In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x, y plane decays to baseline at the end of the scan, which typically is about 5T(2) after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5T(2). However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded with a total scan period of 5T(2), even if some spins are excited later in the scan. This scan time is similar to polyphase excitation methods. The peak power required for either polyphase excitation or rapid frequency scans is substantially smaller than for pulsed EPR. The use of an arbitrary waveform generator (AWG) and cross loop resonator facilitated implementation of the rapid frequency scan experiments reported here. The use of constant continuous low B(1), periodic excitation waveform, and constant external magnetic field is similar to polyphase excitation, but could be implemented without the AWG that is required for polyphase excitation.

Indexed as

AlgorithmsComputer SimulationCrystallizationElectrochemistryElectromagnetic FieldsElectron Spin Resonance SpectroscopyFourier AnalysisSignal Processing, Computer-Assisted

Identifiers

PMID21664848
PMCPMC3145835
OpenAlexW2036777425

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.