Evidence map›Paper›PMID 21645966›Full record

ArticleUltrasound in medicine & biology2011

Acoustic radiation force-driven assessment of myocardial elasticity using the displacement ratio rate (DRR) method.

Richard R Bouchard, Stephen J Hsu, Mark L Palmeri, Ned C Rouze, Kathryn R Nightingale, Gregg E Trahey

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Review
  3. Biomedical physics & engineering express · 2018
    Article
  4. Article
  5. Ultrafast Harmonic Coherent Compound (UHCC) Imaging for High Frame Rate Echocardiography and Shear-Wave Elastography.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2016
    Article
  6. Article
  7. High-contrast ultrafast imaging of the heart.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2014
    Article
  8. Intracardiac acoustic radiation force impulse (ARFI) and shear wave imaging in pigs with focal infarctions.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2013
    Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Richard R BouchardDepartment of Biomedical Engineering, Duke University, Durham, NC, USA. rrb@duke.edu
Stephen J Hsu
Mark L Palmeri
Ned C Rouze
Kathryn R Nightingale
Gregg E Trahey

Funding

Acoustic Radiation Force Impulse (ARFI) Imaging of Cardiac TissueR37HL096023 · NHLBI · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2009 to 2018
$5.2M
NHLBI NIH HHS R37 HL096023
6 · The paper itself

Abstract

A noninvasive method of characterizing myocardial stiffness could have significant implications in diagnosing cardiac disease. Acoustic radiation force (ARF)-driven techniques have demonstrated their ability to discern elastic properties of soft tissue. For the purpose of myocardial elasticity imaging, a novel ARF-based imaging technique, the displacement ratio rate (DRR) method, was developed to rank the relative stiffnesses of dynamically varying tissue. The basis and performance of this technique was demonstrated through numerical and phantom imaging results. This new method requires a relatively small temporal (<1 ms) and spatial (tenths of mm(2)) sampling window and appears to be independent of applied ARF magnitude. The DRR method was implemented in two in vivo canine studies, during which data were acquired through the full cardiac cycle by imaging directly on the exposed epicardium. These data were then compared with results obtained by acoustic radiation force impulse (ARFI) imaging and shear wave velocimetry, with the latter being used as the gold standard. Through the cardiac cycle, velocimetry results portray a range of shear wave velocities from 0.76-1.97 m/s, with the highest velocities observed during systole and the lowest observed during diastole. If a basic shear wave elasticity model is assumed, such a velocity result would suggest a period of increased stiffness during systole (when compared with diastole). Despite drawbacks of the DRR method (i.e., sensitivity to noise and limited stiffness range), its results predicted a similar cyclic stiffness variation to that offered by velocimetry while being insensitive to variations in applied radiation force.

Indexed as

AcousticsAnimalsDisease Models, AnimalDogsElasticity Imaging TechniquesElastic ModulusElectrocardiographyFinite Element AnalysisHeart DiseasesImaging, Three-DimensionalMyocardial ContractionPhantoms, Imaging

Identifiers

PMID21645966
PMCPMC3118908

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked