Evidence map›Paper›PMID 21639522›Full record

ArticleThe Review of scientific instruments2011

Vacuum compatible sample positioning device for matrix assisted laser desorption∕ionization Fourier transform ion cyclotron resonance mass spectrometry imaging.

Konstantin Aizikov, Donald F Smith, David A Chargin, Sergei Ivanov, Tzu-Yung Lin, Ron M A Heeren, Peter B O'Connor

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Konstantin AizikovCardiovascular Proteomics Center, Boston University School of Medicine, 670 Albany Street, Room 504 Boston, Massachusetts 02118, USA.
Donald F Smith
David A Chargin
Sergei Ivanov
Tzu-Yung Lin
Ron M A Heeren
Peter B O'Connor

Funding

XI INTERNATIONAL SYMPOSIUM ON AMYLOIDOSISP41RR010888 · NCRR · BOSTON UNIVERSITY MEDICAL CAMPUS · PI COSTELLO, CATHERINE E. · 1996 to 2011
$18.6M
Defining the IsoAspartomeR01GM078293 · NIGMS · BOSTON UNIVERSITY MEDICAL CAMPUS · PI LIN, CHENG · 2007 to 2011
$1.5M
NHLBI PROTEOMICS INITIATIVE-N01HV28178N01HV028178 · HV · BOSTON UNIVERSITY MEDICAL CAMPUS · PI COSTELLO, CATHERINE E. · 2002 to 2006
–
STRUCTURAL CHARACTERIZATION OF THE APOPROTEIN E RECEPTORR01HL028178 · NHLBI · J. DAVID GLADSTONE INSTITUTES · PI INNERARITY, THOMAS L. · 1986 to 1988
–
NCRR NIH HHS P41 RR010888NCRR NIH HHS P41RR10888NHLBI NIH HHS N01 HV028178NIGMS NIH HHS R01 GM078293NIGMS NIH HHS R01GM078293
6 · The paper itself

Abstract

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in ∼1 × 10(-8) mbar vacuum. The range of motion is set to 100 mm × 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption∕ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The "oversampling" MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

Indexed as

Fourier AnalysisAnimalsCyclotronsMolecular ImagingRatsSerine EndopeptidasesSoftwareSpectrometry, Mass, Matrix-Assisted Laser Desorption-Ionizationmicrobial serine proteinasesSerine Endopeptidases

Identifiers

PMID21639522
PMCPMC3117896

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.