ArticleBiomedical engineering online2011
Focal laser ablation of prostate cancer: numerical simulation of temperature and damage distribution.
Article in Biomedical engineering online, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 59 citations in OpenAlex.
- From Simulation to Surgery: Comprehensive Validation of an Optical Sensor for Monitoring Focal Laser Ablation of Solid Organ Tumors.IEEE sensors journal · 2024Article
- The LMIT: Light-mediated minimally-invasive theranostics in oncology.Theranostics · 2024Review
- Treatment Modelling of a 3D Tumour in Brain by Laser-Induced Interstitial Thermotherapy.Journal of lasers in medical sciences · 2023Article
- The Rationale for "Laser-Induced Thermal Therapy (LITT) and Intratumoral Cisplatin" Approach for Cancer Treatment.International journal of molecular sciences · 2022Review
- The prostate cancer focal therapy.Gland surgery · 2018Review
- Article
- Investigation of factors affecting hypothermic pelvic tissue cooling using bio-heat simulation based on MRI-segmented anatomic models.Computer methods and programs in biomedicine · 2015Article
- Identifying QuantitativeNeurocomputing · 2014Article
- Photo-magnetic imaging: resolving optical contrast at MRI resolution.Physics in medicine and biology · 2013Article
- Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling.Lasers in medical science · 2013Article
- Computational analysis of endometrial photocoagulation with diffusing optical device.Biomedical optics express · 2013Article
- Focal laser ablation of prostate cancer: definition, needs, and future.Advances in urology · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe use of minimally invasive ablative techniques in the management of patients with low grade and localized prostate tumours could represent a treatment option between active surveillance and radical therapy. Focal laser ablation (FLA) could be one of these treatment modalities. Dosimetry planning and conformation of the treated area to the tumor remain major issues, especially when, several fibers are required. An effective method to perform pre-treatment planning of this therapy is computer simulation. In this study we present an in vivo validation of a mathematical model.
methodsThe simulation model is based on finite elements method (FEM) to solve the bio-heat and the thermal damage equations. Laser irradiation was performed with a 980 nm laser diode system (5 W, 75 s). Light was transmitted using a cylindrical diffusing fiber inserted inside a preclinical animal prostate cancer model induced in Copenhagen rats. Non-enhanced T2-weighted and dynamic gadolinium-enhanced T1-weighted MR imaging examinations were performed at baseline and 48 hours after the procedure. The model was validated by comparing the simulated necrosis volume to the results obtained in vivo on (MRI) and by histological analysis. 3 iso-damage temperatures were considered 43° C, 45° C and 50° C.
resultsThe mean volume of the tissue necrosis, estimated from the histological analyses was 0.974 ± 0.059 cc and 0.98 ± 0.052 cc on the 48 h MR images. For the simulation model, volumes were: 1.38 cc when T = 43° C, 1.1 cc for T = 45°C and 0.99 cc when T = 50 C°.
conclusionsIn this study, a clear correlation was established between simulation and in vivo experiments of FLA for prostate cancer.Simulation is a promising planning technique for this therapy. It needs further more evaluation to allow to FLA to become a widely applied surgical method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.