ArticleAJNR. American journal of neuroradiology2011
Stent placement for flow restoration in acute ischemic stroke: a single-center experience with the Solitaire stent system.
Article in AJNR. American journal of neuroradiology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 83 citations in OpenAlex.
- Inter- and intraobserver agreement in scoring angiographic results of intra-arterial stroke therapy.AJNR. American journal of neuroradiology · 2014Trial
- Mechanical thrombectomy with stent retrievers in acute basilar artery occlusion.AJNR. American journal of neuroradiology · 2014Trial
- Stent retrievers in acute ischemic stroke: complications and failures during the perioperative period.AJNR. American journal of neuroradiology · 2014Trial
- Potential for the use of the Solitaire stent for recanalization of middle cerebral artery occlusion without a susceptibility vessel sign.AJNR. American journal of neuroradiology · 2014Trial
- Mechanical thrombectomy in acute stroke: prospective pilot trial of the solitaire FR device while under conscious sedation.AJNR. American journal of neuroradiology · 2013Trial
- Comparison of stent-retriever devices versus the Merci retriever for endovascular treatment of acute stroke.AJNR. American journal of neuroradiology · 2013Trial
- Technical feasibility and application of mechanical thrombectomy with the Solitaire FR Revascularization Device in acute basilar artery occlusion.AJNR. American journal of neuroradiology · 2013Trial
- Optional or optimal? off-label stenting for intracranial atherosclerotic stenosis: A scoping review.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- The Railroad Technique: A Mechanical Thrombectomy Approach Using Serial Deployment of Two Stent Retrievers for Tandem ICA-M1 Embolic Occlusion.Journal of neuroendovascular therapy · 2025Article
- Therapeutic Advancements in the Endovascular Management of Acute Ischemic Stroke.Stroke (Hoboken, N.J.) · 2021Review
- Efficacy of Solitaire AB stent-release angioplasty in acute middle cerebral artery atherosclerosis obliterative cerebral infarction.World journal of clinical cases · 2021Article
- Solitaire AB stent-angioplasty for stenoses in perforator rich segments: A single-center experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020Article
- A New Era of Extended Time Window Acute Stroke Interventions Guided by Imaging.The Neurohospitalist · 2020Review
- Efficacy and Safety of REVIVE SE Thrombectomy Device for Acute Ischemic Stroke: River JAPAN (Reperfuse Ischemic Vessels with Endovascular Recanalization Device in Japan).Neurologia medico-chirurgica · 2018Observational
- Feasibility of Permanent Stenting with Solitaire FR as a Rescue Treatment for the Reperfusion of Acute Intracranial Artery Occlusion.AJNR. American journal of neuroradiology · 2018Article
- Mechanical Thrombectomy with Solitaire Stent Retrieval for Acute Cardioembolic Stroke.Journal of Korean Neurosurgical Society · 2017Article
- Mechanical removal of a refluxed Onyx piece from the middle cerebral artery using the Solitaire Stent: Technical report.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2017Article
- Clinical and radiological outcome after mechanical thrombectomy in acute ischemic stroke: What matters?The neuroradiology journal · 2016Article
- The pREset Stent Retriever for Endovascular Treatment of Stroke Caused by MCA Occlusion: Safety and Clinical Outcome.Clinical neuroradiology · 2016Article
- Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients.BMC neurology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeIn acute thromboembolic stroke, mechanical recanalization with stents may result in immediate flow restoration. The Solitaire stent can be used both for flow restoration and thrombectomy. In this single-center experience, we report safety and efficacy data on the application of the Solitaire stent. MATERIALS AND
methodsBetween March 2009 and July 2010, 18 patients were treated with the Solitaire stent. To evaluate perfusion of the occluded vessel segment before and after the intervention, the TICI score was used (0-3). Clinical outcome was assessed by using the mRS at discharge.
resultsOverall, recanalization was successful in 16 of 18 patients (88.8%). There were no procedure-related complications. Mean TICI score after the intervention was 2.3 ± 0.8. In 5 patients, reocclusion of the treated vessel occurred immediately after retrieval of the temporarily opened stent, and permanent stent deployment was performed to maintain stable perfusion. In 3 patients, hemorrhage occurred after successful recanalization. Five patients died (infarction, n = 3; hemorrhage, n = 1; organ failure, n = 1). A good clinical outcome (mRS ≤2) was achieved in 33.3% of the patients, 5.5% had a moderate outcome (mRS, 3/4), and 61.2% had a poor outcome or died (mRS, 5/6).
conclusionsApplication of the Solitaire stent in acute stroke results in a high recanalization rate (88.8%) without procedural complications and with a good outcome in one-third of patients. These results encourage further evaluation of the stent in larger patient populations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.