Evidence map›Paper›PMID 21550110›Full record

ArticleBiomaterials2011

The use of glass substrates with bi-functional silanes for designing micropatterned cell-secreted cytokine immunoassays.

Jeong Hyun Seo, Li-Jung Chen, Stanislav V Verkhoturov, Emile A Schweikert, Alexander Revzin

Open access · greenAbstract read
In one paragraph

Article in Biomaterials, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jeong Hyun SeoDepartment of Biomedical Engineering, University of California, Davis, CA 95616, USA.
Li-Jung Chen
Stanislav V Verkhoturov
Emile A Schweikert
Alexander Revzin
Texas A&M University · USUniversity of California, Davis · US

Funding

Designing a Microenvironment Niche for Liver-Specific Differentiation of hESCsR01DK079977 · NIDDK · UNIVERSITY OF CALIFORNIA AT DAVIS · PI REVZIN, ALEXANDER · 2010 to 2014
$1.8M
NIDDK NIH HHS R01 DK079977
6 · The paper itself

Abstract

It is often desirable to sequester cells in specific locations on the surface and to integrate sensing elements next to the cells. In the present study, surfaces were fabricated so as to position cytokine sensing domains inside non-fouling poly(ethylene glycol) (PEG) hydrogel microwells. Our aim was to increase sensitivity of micropatterned cytokine immunoassays through covalent attachment of biorecognition molecules. To achieve this, glass substrates were functionalized with a binary mixture of acrylate- and thiol-terminated methoxysilanes. During subsequent hydrogel photopatterning steps, acrylate moieties served to anchor hydrogel microwells to glass substrates. Importantly, glass attachment sites within the microwells contained thiol groups that could be activated with a hetero-bifunctional cross-linker for covalent immobilization of proteins. After incubation with fluorescently-labeled avidin, microwells fabricated on a mixed acryl/thiol silane layer emitted ∼ 6 times more fluorescence compared to microwells fabricated on an acryl silane alone. This result highlighted the advantages of covalent attachment of avidin inside the microwells. To create cytokine immunoassays, micropatterned surfaces were incubated with biotinylated IFN-γ or TNF-α antibodies (Abs). Micropatterned immunoassays prepared in this manner were sensitive down to 1 ng/ml or 60 pM IFN-γ. To further prove utility of this biointerface design, macrophages were seeded into 30 μm diameter microwells fabricated on either bi-functional (acryl/thiol) or mono-functional silane layers. Both types of microwells were coated with avidin and biotin-anti-TNF-α prior to cell seeding. Short mitogenic activation followed by immunostaining for TNF-α revealed that microwells created on bi-functional silane layer had 3 times higher signal due to macrophage-secreted TNF-α compared to microwells fabricated on mono-functional silane. The rational design of cytokine-sensing surfaces described here, will be leveraged in the future for rapid detection of multiple cytokines secreted by individual immune cells.

Indexed as

AcrylatesAnimalsAntibodiesAvidinBiotinCell Line, TumorCytokinesEukaryotic CellsFluorescent DyesGlassHumansHydrogelsImmunoassayInterferon-gammaMacrophagesMaleimides3-acryloxypropyltrimethoxysilane(3-mercaptopropyl)trimethoxysilaneAcrylatesAntibodiesAvidinBiotinCytokinesFluorescent DyesHydrogelsInterferon-gammaMaleimidesneutravidinOrganosilicon CompoundsPolyethylene GlycolsSilanesStreptavidinTetradecanoylphorbol AcetateTumor Necrosis Factor-alpha

Identifiers

PMID21550110
PMCPMC3268061
OpenAlexW2117255590

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.