ArticleCirculation. Cardiovascular imaging2011
X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization.
Article in Circulation. Cardiovascular imaging, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Results from an international multi-center prospective registry of cardiac catheterizations and percutaneous cardiac interventions guided with three-dimensional imaging.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026Article
- PICS/AEPC/APPCS/CSANZ/SCAI/SOLACI: Expert Consensus Statement on Cardiac Catheterization for Pediatric Patients and Adults With Congenital Heart Disease.Journal of the Society for Cardiovascular Angiography & Interventions · 2024Article
- X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019Article
- Innovative interventional catheterization techniques for congenital heart disease.Translational pediatrics · 2018Review
- Prospective evaluation of MR overlay on real-time fluoroscopy for percutaneous extremity biopsies of bone lesions visible on MRI but not on CT in children in the interventional radiology suite.Pediatric radiology · 2018Article
- Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2018Article
- Real-time three dimensional CT and MRI to guide interventions for congenital heart disease and acquired pulmonary vein stenosis.The international journal of cardiovascular imaging · 2017Article
- Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization : 3D image fusion for interventions in CHD.Pediatric cardiology · 2017Article
- Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization.Pediatric cardiology · 2016Article
- Early experience with X-ray magnetic resonance fusion for low-flow vascular malformations in the pediatric interventional radiology suite.Pediatric radiology · 2016Article
- Interventional CMR: Clinical applications and future directions.Current cardiology reports · 2015Review
- Roadmaps show the way: coregistration to enhance structural heart interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2013Article
- Multimodality Imaging in Congenital Heart Disease: an Update.Current cardiovascular imaging reports · 2012Review
- Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization.Annals of pediatric cardiologyArticle
- Multimodality 3-dimensional image integration for congenital cardiac catheterization.Methodist DeBakey cardiovascular journalReview
- Intraoperative Imaging and Image Fusion for Venous Interventions.Methodist DeBakey cardiovascular journalReview
Corrections and comments
- Commented on by
Authors and funding
9 authors.
Funding
Abstract
backgroundX-ray magnetic resonance fusion (XMRF) allows for use of 3D data during cardiac catheterization. However, to date, technical requirements have limited the use of this modality in clinical practice. We report on a new internal-marker XMRF method that we have developed and describe how we used XMRF during cardiac catheterization in congenital heart disease. METHODS AND
resultsXMRF was performed in a phantom and in 23 patients presenting for cardiac catheterization who also needed cardiac MRI for clinical reasons. The registration process was performed in < 5 minutes per patient, with minimal radiation (0.004 to 0.024 mSv) and without contrast. Registration error was calculated in a phantom and in 8 patients using the maximum distance between angiographic and 3D model boundaries. In the phantom, the measured error in the anteroposterior projection had a mean of 1.15 mm (standard deviation, 0.73). The measured error in patients had a median of 2.15 mm (interquartile range, 1.65 to 2.56 mm). Internal markers included bones, airway, image artifact, calcifications, and the heart and vessel borders. The MRI data were used for road mapping in 17 of 23 (74%) cases and camera angle selection in 11 of 23 (48%) cases.
conclusionsInternal marker-based registration can be performed quickly, with minimal radiation, without the need for contrast, and with clinically acceptable accuracy using commercially available software. We have also demonstrated several potential uses for XMRF in routine clinical practice. This modality has the potential to reduce radiation exposure and improve catheterization outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.