ArticleAnalytical chemistry2011
Validation of arrayed imaging reflectometry biosensor response for protein-antibody interactions: cross-correlation of theory, experiment, and complementary techniques.
Article in Analytical chemistry, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Lambda Theta Reflectometry: A New Technique for Measuring Optical Film Thickness in Planar Protein Arrays.ACS sensors · 2025Article
- Array-based analysis of SARS-CoV-2, other coronaviruses, and influenza antibodies in convalescent COVID-19 patients.Biosensors & bioelectronics · 2020Article
- A Stable Biotin-Streptavidin Surface Enables Multiplex, Label-Free Protein Detection by Aptamer and Aptamer-Protein Arrays Using Arrayed Imaging Reflectometry.Sensors (Basel, Switzerland) · 2020Article
- Immunosensor-based label-free and multiplex detection of influenza viruses: State of the art.Biosensors & bioelectronics · 2019Review
- Crowd on a Chip: Label-Free Human Monoclonal Antibody Arrays for Serotyping Influenza.Analytical chemistry · 2018Article
- Functionalized Polymer Microgel Particles Enable Customizable Production of Label-Free Sensor Arrays.Analytical chemistry · 2015Article
- Article
- Examining the interactions of the splicing factor MBNL1 with target RNA sequences via a label-free, multiplex method.Analytical chemistry · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
One of the critical steps in the development of an analytical technique is to confirm that its experimental response correlates with predictions derived from the theoretical framework on which it is based. This validates the technique quantitatively and, in the case of a biosensor, facilitates a correlation of the sensor's output signal to the concentration of the analyte being tested. Herein we report studies demonstrating that the quantitative response of arrayed imaging reflectometry (AIR), a highly sensitive label-free biosensing method, is a predictable function of the probe and analyte properties. We first incorporated a standard one-site Langmuir binding model describing probe-analyte interactions at the surface into the theoretical model for thickness-dependent reflectance in AIR. This established a hypothetical correlation between the analyte concentration and the AIR response. Spectroscopic ellipsometry, surface plasmon resonance, and AIR were then used to validate this model for two biomedically important proteins, fibroblast growth factor-2 and vascular endothelial growth factor. While our studies demonstrated that the 1:1 one-site Langmuir model accurately described the observed response of macrospot AIR arrays, either a two-site Langmuir model or a Sips isotherm better described the behavior of AIR microarrays. These studies confirmed the quantitative performance of AIR across a range of probe-analyte affinities. Furthermore, the methodology developed here can be extended to other label-free biosensing platforms, thus facilitating a more accurate and quantitative interpretation of the sensor response.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.