Evidence map›Paper›PMID 21499183›Full record

Trial reportPediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies2011

Value of continuous glucose monitoring for minimizing severe hypoglycemia during tight glycemic control.

Garry M Steil, Monica Langer, Karen Jaeger, Jamin Alexander, Michael Gaies, Michael S D Agus

Registry-linked trialOpen access · greenAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02300285 (Efficacy of Continuous Glucose Monitoring in Neonates With Hypoglycemia), which is not on this map. Cited by 20 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 2 pooled it
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02300285 naterminatednot on this mapstarted 2015, after this paper: background citation

Efficacy of Continuous Glucose Monitoring in Neonates With Hypoglycemia

TypeinterventionalSponsorBoston Children's HospitalRan2015 to 2018Enrolled6ConditionsHypoglycemia, Newborn MorbidityArmsContinuous Glucose Monitoring
3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 2 syntheses or guidelines pooled it, 38 citations in OpenAlex.

  1. Guideline
  2. Hypoglycemia in critically ill children.Journal of diabetes science and technology · 2012
    Pooled it
  3. Trial
  4. Tight Glycemic Control in Critically Ill Children.The New England journal of medicine · 2017
    Trial
  5. Trial
  6. Design and rationale of safe pediatric euglycemia after cardiac surgery: a randomized controlled trial of tight glycemic control after pediatric cardiac surgery.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2013
    Trial
  7. Trial
  8. Article
  9. Review
  10. Article
  11. Continuous Glucose Monitoring in the Intensive Care Unit.Journal of diabetes science and technology · 2023
    Article
  12. Continuous Glucose Monitoring in the Hospital.Endocrinology and metabolism (Seoul, Korea) · 2021
    Review
  13. Article
  14. Article
  15. Tight Glycemic Control in the Pediatric Intensive Care Unit.Journal of pediatric intensive care · 2016
    Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Tight glycemic control and cardiovascular effects in type 2 diabetic patients.Heart views : the official journal of the Gulf Heart Association
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Garry M SteilDepartment of Surgery and Medicine, Children's Hospital, Boston, MA, USA.
Monica Langer
Karen Jaeger
Jamin Alexander
Michael Gaies
Michael S D Agus
Harvard University Press · US

Funding

HARVARD CLINICAL AND TRANSLATIONAL SCIENCE CENTER (UL1)UL1RR025758 · NCRR · HARVARD MEDICAL SCHOOL · PI NADLER, LEE MARSHALL · 2008 to 2011
$91.4M
ROLE OF DIETARY CONSTITUENTS ON GENE EXPRESSION IN INTESTINAL EPITHELIUMP30DK040561 · NIDDK · MASSACHUSETTS GENERAL HOSPITAL · PI CHRISTOPHER P DUGGAN · 1994 to 2026
$31.6M
WIRELESS CAPSULE ENDOSCOPY TO EVALUATE THE SMALL INTESTINE M01RR002172 · NCRR · CHILDREN'S HOSPITAL BOSTON · PI MANDELL, JAMES WILLIAM · 1985 to 2008
$16.0M
SPECS: Safe Pediatric Euglycemia in Cardiac SurgeryR01HL088448 · NHLBI · BOSTON CHILDREN'S HOSPITAL · PI AGUS, MICHAEL SD · 2007 to 2011
$4.0M
NCRR NIH HHS M01 RR002172NCRR NIH HHS MO1-RR02172NCRR NIH HHS UL1 RR025758NCRR NIH HHS UL1-RR025758NHLBI NIH HHS R01 HL088448NHLBI NIH HHS R01HL88448NIDDK NIH HHS P30 DK040561
6 · The paper itself

Abstract

objectiveTight glycemic control can potentially reduce morbidity and mortality in the intensive care unit but increases the risk of hypoglycemia. The most effective means to avoid hypoglycemia is to obtain frequent blood glucose samples, but this increases the burden to nursing staff. The objective of this study was to assess the ability of a real-time continuous glucose monitor to reduce hypoglycemia (blood glucose <60 mg/dL [3.3 mmol/L]) during standard care or tight glycemic control effected with a proportional integral derivative insulin titration algorithm.

designReal-time continuous glucose monitor profiles obtained from an ongoing prospective randomized trial of tight glycemic control were retrospectively analyzed to determine whether the continuous glucose measure had prevented instances of hypoglycemia.

settingCardiac intensive care unit. PATIENTS: Children 3 yrs of age or younger undergoing cardiac surgery were studied.

interventionsIntravenous insulin infusion and rescue glucose guided by the real-time continuous glucose monitor and the proportional integral derivative algorithm in the tight glycemic control arm (n = 155; target glucose 80-110 mg/dL [4.4-6.1 mmol/L]) and the real-time continuous glucose monitor in the standard care arm (n = 156). MEASUREMENTS AND MAIN

resultsNo reduction in hypoglycemia was observed with real-time continuous glucose monitor alarms set at 60 mg/dL (3.3 mmol/L) (zero of 19 occurrences of blood glucose <60 mg/dL [3.3 mmol/L] detected); 18 of 40 subsequent incidences of hypoglycemia were detected after the alarm threshold was increased to 70 mg/dL (3.9 mmol/L). In the tight glycemic control arm, eight incidences were reduced in duration and an additional eight events were prevented with intravenous glucose. In the standard care arm, three of nine occurrences of hypoglycemia were detected with the duration reduced in all cases. On average, one to two false hypoglycemia alarms were observed in each patient.

conclusionsThe real-time continuous glucose monitor in combination with proportional integral derivative control can reduce hypoglycemia during tight glycemic control. The real-time continuous glucose monitor can also reduce hypoglycemia during standard care. However, false alarms increase the overall nursing workload.

Indexed as

Blood GlucoseChild, PreschoolHumansHypoglycemiaInfantIntensive Care Units, PediatricMonitoring, PhysiologicProspective StudiesSeverity of Illness IndexBlood Glucose

Identifiers

PMID21499183
PMCPMC3705721
OpenAlexW2089077606

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.