ArticleLangmuir : the ACS journal of surfaces and colloids2011
Rapid microarray detection of DNA and proteins in microliter volumes with surface plasmon resonance imaging measurements.
Article in Langmuir : the ACS journal of surfaces and colloids, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Multianalyte nano-biosensor diagnostics: advances through microfluidic and AI integration.Frontiers in bioengineering and biotechnology · 2025Review
- A Microwell-Printing Fabrication Strategy for the On-Chip Templated Biosynthesis of Protein Microarrays for Surface Plasmon Resonance Imaging.The journal of physical chemistry. C, Nanomaterials and interfaces · 2016Article
- Surface Enzyme Chemistries for Ultrasensitive Microarray Biosensing with SPR Imaging.Langmuir : the ACS journal of surfaces and colloids · 2015Article
- Evaluation of optical detection platforms for multiplexed detection of proteins and the need for point-of-care biosensors for clinical use.Sensors (Basel, Switzerland) · 2014Review
- Zeptomole detection of DNA nanoparticles by single-molecule fluorescence with magnetic field-directed localization.Analytical biochemistry · 2012Article
- On-chip synthesis of protein microarrays from DNA microarrays via coupled in vitro transcription and translation for surface plasmon resonance imaging biosensor applications.Journal of the American Chemical Society · 2012Article
- On-chip synthesis of RNA aptamer microarrays for multiplexed protein biosensing with SPR imaging measurements.Langmuir : the ACS journal of surfaces and colloids · 2012Article
- Screening of aptamers on microfluidic systems for clinical applications.Sensors (Basel, Switzerland) · 2012Review
- Molecular imaging with nucleic acid aptamers.Current medicinal chemistry · 2011Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
A four-chamber microfluidic biochip is fabricated for the rapid detection of multiple proteins and nucleic acids from microliter volume samples with the technique of surface plasmon resonance imaging (SPRI). The 18 mm × 18 mm biochip consists of four 3 μL microfluidic chambers attached to an SF10 glass substrate, each of which contains three individually addressable SPRI gold thin film microarray elements. The 12-element (4 × 3) SPRI microarray consists of gold thin film spots (1 mm(2) area; 45 nm thickness), each in individually addressable 0.5 μL volume microchannels. Microarrays of single-stranded DNA and RNA (ssDNA and ssRNA, respectively) are fabricated by either chemical and/or enzymatic attachment reactions in these microchannels; the SPRI microarrays are then used to detect femtomole amounts (nanomolar concentrations) of DNA and proteins (ssDNA binding protein and thrombin via aptamer-protein bioaffinity interactions). Microarrays of ssRNA microarray elements are also used for the ultrasensitive detection of zeptomole amounts (femtomolar concentrations) of DNA via the technique of RNase H-amplified SPRI. Enzymatic removal of ssRNA from the surface due to the hybridization adsorption of target ssDNA is detected as a reflectivity decrease in the SPR imaging measurements. The observed reflectivity loss is proportional to the log of the target ssDNA concentration with a detection limit of 10 fM or 30 zeptomoles (18 000 molecules). This enzymatic amplified ssDNA detection method is not limited by diffusion of ssDNA to the interface, and thus is extremely fast, requiring only 200 s in the microliter volume format.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials