ArticleLab on a chip2011
Hybrid electrokinetic manipulation in high-conductivity media.
Article in Lab on a chip, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
33 citing papers in PubMed.
- Electropatterning-Contemporary developments for selective particle arrangements employing electrokinetics.Electrophoresis · 2023Review
- Manipulation with sound and vibration: A review on the micromanipulation system based on sub-MHz acoustic waves.Ultrasonics sonochemistry · 2023Review
- Diagnosis of Bloodstream Infections: An Evolution of Technologies towards Accurate and Rapid Identification and Antibiotic Susceptibility Testing.Antibiotics (Basel, Switzerland) · 2022Review
- Article
- A Rapid Single-Cell Antimicrobial Susceptibility Testing Workflow for Bloodstream Infections.Biosensors · 2021Article
- Insulator Based Dielectrophoresis: Micro, Nano, and Molecular Scale Biological Applications.Sensors (Basel, Switzerland) · 2020Review
- Sensor Based on PZT Ceramic Resonator with Lateral Electric Field for Immunodetectionof Bacteria in the Conducting Aquatic Environment.Sensors (Basel, Switzerland) · 2020Article
- Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study.Micromachines · 2020Article
- AC Electrothermal Effect in Microfluidics: A Review.Micromachines · 2019Review
- An Experimental Study of 3D Electrode-Facilitated Particle Traffic Flow-Focusing Driven by Induced-Charge Electroosmosis.Micromachines · 2019Article
- Joule heating-induced particle manipulation on a microfluidic chip.Biomicrofluidics · 2019Article
- A High-Throughput Electrokinetic Micromixer via AC Field-Effect Nonlinear Electroosmosis Control in 3D Electrode Configurations.Micromachines · 2018Article
- Review: Microbial analysis in dielectrophoretic microfluidic systems.Analytica chimica acta · 2017Review
- Long-range electrothermal fluid motion in microfluidic systems.International journal of heat and mass transfer · 2016Article
- Dielectrophoresis-Mediated Electrodeformation as a Means of Determining Individual Platelet Stiffness.Annals of biomedical engineering · 2016Article
- AC Electrokinetics of Physiological Fluids for Biomedical Applications.Journal of laboratory automation · 2015Review
- Combining electrochemical sensors with miniaturized sample preparation for rapid detection in clinical samples.Sensors (Basel, Switzerland) · 2014Review
- Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma.Electrophoresis · 2014Article
- Rapid electrokinetic isolation of cancer-related circulating cell-free DNA directly from blood.Clinical chemistry · 2014Article
- Advances and challenges in biosensor-based diagnosis of infectious diseases.Expert review of molecular diagnostics · 2014Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
This study reports a hybrid electrokinetic technique for label-free manipulation of pathogenic bacteria in biological samples toward medical diagnostic applications. While most electrokinetic techniques only function in low-conductivity buffers, hybrid electrokinetics enables effective operation in high-conductivity samples, such as physiological fluids (∼1 S m(-1)). The hybrid electrokinetic technique combines short-range electrophoresis and dielectrophoresis, and long-range AC electrothermal flow to improve its effectiveness. The major technical hurdle of electrode instability for manipulating high conductivity samples is tackled by using a Ti-Au-Ti sandwich electrode and a 3-parallel-electrode configuration is designed for continuous isolation of bacteria. The device operates directly with biological samples including urine and buffy coats. We show that pathogenic bacteria and biowarfare agents can be concentrated for over 3 orders of magnitude using hybrid electrokinetics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.