ArticleUrological research2011
The efficacy of a novel antibacterial hydroxyapatite nanoparticle-coated indwelling urinary catheter in preventing biofilm formation and catheter-associated urinary tract infection in rabbits.
Article in Urological research, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 30 citations in OpenAlex.
- Combination-Based Biofunctional Coatings for Veterinary Biofilm-Associated Infections.Antibiotics (Basel, Switzerland) · 2026Review
- Perspectives on Usage of Functional Nanomaterials in Antimicrobial Therapy for Antibiotic-Resistant Bacterial Infections.ACS omega · 2023Review
- Effective Treatments of UTI-Is Intravesical Therapy the Future?Pathogens (Basel, Switzerland) · 2023Review
- Emerging evidence-based innovative approaches to control catheter-associated urinary tract infection: a review.Frontiers in cellular and infection microbiology · 2023Review
- Self-Disinfecting Urethral Catheter to Overcome Urinary Infections: From Antimicrobial Photodynamic Action to Antibacterial Biochemical Entities.Microorganisms · 2022Review
- Nanoparticles as Potential Novel Therapies for Urinary Tract Infections.Frontiers in cellular and infection microbiology · 2021Review
- Evaluation of Antimicrobial Durability and Anti-Biofilm Effects in Urinary Catheters AgainstBalkan medical journal · 2017Article
- Azithromycin-Ciprofloxacin-Impregnated Urinary Catheters Avert Bacterial Colonization, Biofilm Formation, and Inflammation in a Murine Model of Foreign-Body-Associated Urinary Tract Infections Caused by Pseudomonas aeruginosa.Antimicrobial agents and chemotherapy · 2017Article
- Sustained Nitric Oxide-Releasing Nanoparticles Interfere with Methicillin-Resistant Staphylococcus aureus Adhesion and Biofilm Formation in a Rat Central Venous Catheter Model.Antimicrobial agents and chemotherapy · 2017Article
- Sustained Nitric Oxide-Releasing Nanoparticles Induce Cell Death in Candida albicans Yeast and Hyphal Cells, Preventing Biofilm Formation In Vitro and in a Rodent Central Venous Catheter Model.Antimicrobial agents and chemotherapy · 2016Article
- Safety of latex urinary catheters for the short time drainage.Urology annals · 2014Article
- Urovision 2020: The future of urology.Indian journal of urology : IJU : journal of the Urological Society of IndiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study was to investigate of the efficacy and reliability of a novel antimicrobial hydroxyapatite (HA) nanoparticle coating of urethral catheters, in the prophylaxis of biofilm formation and bacteriuria in rabbits. A total of 60 male rabbits were randomized to the control and study groups and each group was divided into three subgroups depending on 3, 5 and 7 days of the urethral catheterization period. The rabbits in the study group were catheterized with Ag(+)-incorporated nano-HA coated urethral catheters and those in the control group with standard silicon-latex urethral catheters. Urine and catheter surface smear samples were conducted for bacteriological analysis. Catheter cross-section samples were undergone measuring of biofilm thickness. Tissue samples of bladder and urethra were inspected for histological changes. The results indicate that at the end of 7 days of the catheterization period, the number of the rabbits with bacteriuria was significantly lower in the study group versus control group (p (¶) = 0.020). The biofilm formation on luminal surface of the catheters was significantly thinner in the study group versus control group, at the end of 5 and 7 days of the catheterization period (0.035 and 0.035, respectively).No histological adverse change or particle penetration was detected in the urothelium. In conclusion, it was observed that Ag(+) + HA nanoparticle coating significantly lowered the incidence of catheter-related bacteriuria and decreased biofilm formation, at the end of 7 days study period. The novel antimicrobial urethral catheter coating appeared to have a potential in the prophylaxis of catheter-induced urinary tract infections.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.