Evidence map›Paper›PMID 21453521›Full record

ArticleMalaria journal2011

Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing.

Rosangela Frita, Maria Rebelo, Ana Pamplona, Ana M Vigario, Maria M Mota, Martin P Grobusch, Thomas Hänscheid

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Malaria journal, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 37 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 4 countries.

Rosangela FritaInstituto de Medicina Molecular, Faculdade de Medicina de Lisboa, Lisbon, Hospital Universitário de Santa Maria, Av, Prof, Egas Moniz, P-1649-028 Lisboa, Portugal.
Maria Rebelo
Ana Pamplona
Ana M Vigario
Maria M Mota
Martin P Grobusch
Thomas Hänscheid
Hospital de Santa Maria · PTUniversity of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMalaria pigment (haemozoin, Hz) has been the focus of diverse research efforts. However, identification of Hz-containing leukocytes or parasitized erythrocytes is usually based on microscopy, with inherent limitations. Flow cytometric detection of depolarized Side-Scatter is more accurate and its adaptation to common bench top flow cytometers might allow several applications. These can range from the ex-vivo and in-vitro detection and functional analysis of Hz-containing leukocytes to the detection of parasitized Red-Blood-Cells (pRBCs) to assess antimalarial activity.

methodsA standard benchtop flow cytometer was adapted to detect depolarized Side-Scatter. Synthetic and Plasmodium falciparum Hz were incubated with whole blood and PBMCs to detect Hz-containing leukocytes and CD16 expression on monocytes. C5BL/6 mice were infected with Plasmodium berghei ANKA or P. berghei NK65 and Hz-containing leukocytes were analysed using CD11b and Gr1 expression. Parasitized RBC from infected mice were identified using anti-Ter119 and SYBR green I and were analysed for depolarized Side Scatter. A highly depolarizing RBC population was monitored in an in-vitro culture incubated with chloroquine or quinine.

resultsA flow cytometer can be easily adapted to detect depolarized Side-Scatter and thus, intracellular Hz. The detection and counting of Hz containing leukocytes in fresh human or mouse blood, as well as in leukocytes from in-vitro experiments was rapid and easy. Analysis of CD14/CD16 and CD11b/Gr1 monocyte expression in human or mouse blood, in a mixed populations of Hz-containing and non-containing monocytes, appears to show distinct patterns in both types of cells. Hz-containing pRBC and different maturation stages could be detected in blood from infected mice. The analysis of a highly depolarizing population that contained mature pRBC allowed to assess the effect of chloroquine and quinine after only 2 and 4 hours, respectively.

conclusionsA simple modification of a flow cytometer allows for rapid and reliable detection and quantification of Hz-containing leukocytes and the analysis of differential surface marker expression in the same sample of Hz-containing versus non-Hz-containing leukocytes. Importantly, it distinguishes different maturation stages of parasitized RBC and may be the basis of a rapid no-added-reagent drug sensitivity assay.

Indexed as

AnimalsCD11b AntigenChloroquineErythrocyte CountErythrocytesFlow CytometryHemeproteinsHumansLeukocyte CountLeukocytesLipopolysaccharide ReceptorsMalariaMicePlasmodium bergheiPlasmodium falciparumQuinineCD11b AntigenChloroquinegranulocyte receptor 1, mouseHemeproteinshemozoinLipopolysaccharide ReceptorsQuinineReceptors, Cell SurfaceReceptors, IgG

Identifiers

PMID21453521
PMCPMC3078904
OpenAlexW2139263029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.