ArticleHeart and vessels2012
Titanium-nitride-oxIde-coated stents multicenter registry in diaBEtic patienTs: the TIBET registry.
Article in Heart and vessels, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- The Mechanical and Electrochemical Stability of Trimethysilane Plasma Nanocoatings Deposited onto Cobalt Chromium Cardiovascular Stents.Materials (Basel, Switzerland) · 2024Article
- Biomedical Applications of Titanium Alloys: A Comprehensive Review.Materials (Basel, Switzerland) · 2023Review
- Effect of sarpogrelate treatment on the prognosis after endovascular therapy for critical limb ischemia.Heart and vessels · 2014Article
Corrections and comments
- Erratum issuedChavarri, Mariano Valdés [corrected to Valdés Chavarri, Mariano]; Minguez, Jose Ramón López [corrected to López-Minguez, Jose Ramón]
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We sought to explore the immediate clinical and angiographic results of the Titan(®) stent implantation in diabetic patients, as well as the major adverse cardiac events (MACE) at 6-month follow-up. We enrolled 156 consecutive diabetic patients admitted to undergo percutaneous intervention for at least one significant (50%) coronary lesion. All lesions were treated with the Titan(®) stent implantation according to the contemporary interventional techniques. Patients were prospectively followed-up for at least 6 months. The primary endpoint was MACE at 6-month follow-up [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR)]. Secondary endpoints included angiographic and clinical procedural success, in-hospital MACE, TLR at 6-month follow-up, and stent thrombosis. The mean age was 66.7 ± 9.6 years, (68.4% males). A total of 197 Titan(®) stents were implanted in 163 lesions. Direct stenting was performed in 45.2% of the cases. The mean stent diameter was 3.1 ± 0.61 mm, and the mean length was 18.0 ± 8.9 mm. Average stent deployment pressure was 13.9 ± 4.2 bars. Angiographic procedural success was achieved in 154 (98.7%) cases, and clinical procedural success was achieved in 153 (98.1%) cases. One patient developed in-hospital non-Q-wave MI following the procedure. Clinical follow-up was completed in 155 (99.4%) patients. Three patients (1.9%) died of a cardiac or unknown cause, and two (1.3%) developed MI. TLR was performed in 11 patients (7.1%). Cumulative MACE at 6-month follow-up occurred in 16 (10.3%) patients. No patient suffered stent thrombosis. Titan(®) stent implantation in diabetic patients achieves an excellent immediate clinical and angiographic outcome, with a low incidence of MACE at mid-term follow-up.
Indexed as
Identifiers
21448677What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.