Trial reportDer Anaesthesist2011
External chest compressions using a mechanical feedback device : cross-over simulation study.
Trial report in Der Anaesthesist, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.
- The effectiveness and perceived value of feedback used in cardiac arrest simulation education: a mixed-method systematic review.Scandinavian journal of trauma, resuscitation and emergency medicine · 2025Pooled it
- Effect of a feedback system on the quality of 2-minute chest compression-only cardiopulmonary resuscitation: a randomised crossover simulation study.The Journal of international medical research · 2020Trial
- Exploring enablers and barriers to the use of chest compression feedback devices in advanced life support: a qualitative study.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Article
- The effect of audiovisual feedback of monitor/defibrillators on percentage of appropriate compression depth and rate during cardiopulmonary resuscitation.BMC anesthesiology · 2023Article
- Real-Time Visual Feedback Device Improves Quality Of Chest Compressions: A Manikin Study.Bulletin of emergency and trauma · 2020Article
- Measuring the effectiveness of a novel CPRcard™ feedback device during simulated chest compressions by non-healthcare workers.Singapore medical journal · 2017Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExternal chest compressions (ECC) are essential components of resuscitation and are usually performed without any adjuncts in professional healthcare. Even for healthcare professionals during in-hospital and out-of-hospital resuscitation poor performance in ECC has been reported in recent years. Although several stand-alone devices have been developed none has been implemented as a standard in patient care. The aim of this study was to examine if the use of a mechanical device providing visual feedback and audible assistance during ECC improves performance of healthcare professionals following minimal and simplified instructions.
methodsIn a prospective, randomized cross-over study 81 healthcare professionals performed ECC for 3 min (in the assumed setting of a secured airway) twice on a manikin (Skillreporter ResusciAnne®, with PC-Skillreporting System Version 1.3.0, Laerdal, Stavanger, Norway) in a mock cardiac arrest scenario. Group 1 (n=40) performed ECC with the device first followed by classic ECC and group 2 (n=41) in the opposite order. Minimal instructions were standardized and provided by video instruction (1 min 38 s). Endpoints were achievement of a mean compression rate between 90 and 110/min and a mean compression depth of 40-50 mm. In addition participants had to answer questionnaires about demographic data, professional experience and recent recommendations for ECC as well as their impression of the device concerning the ease of use and their personal level of confidence. Data were analyzed for group-related and inter-group differences using SAS (Version 9.1.3, SAS Institute, Cary, NC).
resultsA total of 81 healthcare professionals regularly involved in resuscitation attempts in pre-hospital or in-hospital settings took part in the study with no differences between the groups: females 35.8% (n=52), emergency medical technicians 32.1% (n=26), anesthesia nurses 32.1% (n=26), physicians (anesthesiology) 45% (n=29). In group 1 33 out of 40 (82.5%; 99.7±4.82/min; 95% confidence interval 95% CI: 98.1-101.2/min) reached the correct range for compression rate and 29/40 (72.5%; 44.0±4.95 mm; 95% CI: 42.4-45.6 mm) the correct compression depth using the assisting device. Afterwards they conducted classic ECC without the device and deteriorated significantly: correct compression rate was achieved by 12/40 (30%, p≤0.0001; 110.6±11.0/min (95% CI: 107.1-114.1/min), while 25/40 (62.5%; 44.5±5.63 mm; 95% CI: 42.6-46.3 mm) met the correct compression depth. Group 2 performed poorer in ECC without assistance and 5/41 (12.2%; 104.5±21.35/min; 95% CI: 97.8-111.3/min) reached the correct rate whereas 21/41 (51.2%; 39.6±7.61 mm; 95% CI: 37.2-42.0 mm) compressed to the appropriate depth. Using the device there was a significant improvement in the second evaluation with 34/41 (82.9%, p≤0.0001; 101.7±4.68/min; 95% CI: 100.2-103.2/min) reaching the correct rate and 36/41 (87.8%, p≤0.0001; 43.9±4.16 mm; 95% CI: 42.6-45.2 mm) the correct depth.
conclusionsThe tested device is easy to use after instruction of less than 3 min and improves ECC performance of healthcare professionals in simulated cardiac arrest with respect to compression depth as well as compression rate.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.