Evidence map›Paper›PMID 21437754›Full record

Trial reportDer Anaesthesist2011

External chest compressions using a mechanical feedback device : cross-over simulation study.

M Skorning, M Derwall, J C Brokmann, D Rörtgen, S Bergrath, J Pflipsen, S Beuerlein, R Rossaint, S K Beckers

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Der Anaesthesist, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

M SkorningBereich Notfallmedizin, Klinik für Anästhesiologie, Universitätsklinikum Aachen, RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Deutschland.
M Derwall
J C Brokmann
D Rörtgen
S Bergrath
J Pflipsen
S Beuerlein
R Rossaint
S K Beckers
Universitätsklinikum Aachen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExternal chest compressions (ECC) are essential components of resuscitation and are usually performed without any adjuncts in professional healthcare. Even for healthcare professionals during in-hospital and out-of-hospital resuscitation poor performance in ECC has been reported in recent years. Although several stand-alone devices have been developed none has been implemented as a standard in patient care. The aim of this study was to examine if the use of a mechanical device providing visual feedback and audible assistance during ECC improves performance of healthcare professionals following minimal and simplified instructions.

methodsIn a prospective, randomized cross-over study 81 healthcare professionals performed ECC for 3 min (in the assumed setting of a secured airway) twice on a manikin (Skillreporter ResusciAnne®, with PC-Skillreporting System Version 1.3.0, Laerdal, Stavanger, Norway) in a mock cardiac arrest scenario. Group 1 (n=40) performed ECC with the device first followed by classic ECC and group 2 (n=41) in the opposite order. Minimal instructions were standardized and provided by video instruction (1 min 38 s). Endpoints were achievement of a mean compression rate between 90 and 110/min and a mean compression depth of 40-50 mm. In addition participants had to answer questionnaires about demographic data, professional experience and recent recommendations for ECC as well as their impression of the device concerning the ease of use and their personal level of confidence. Data were analyzed for group-related and inter-group differences using SAS (Version 9.1.3, SAS Institute, Cary, NC).

resultsA total of 81 healthcare professionals regularly involved in resuscitation attempts in pre-hospital or in-hospital settings took part in the study with no differences between the groups: females 35.8% (n=52), emergency medical technicians 32.1% (n=26), anesthesia nurses 32.1% (n=26), physicians (anesthesiology) 45% (n=29). In group 1 33 out of 40 (82.5%; 99.7±4.82/min; 95% confidence interval 95% CI: 98.1-101.2/min) reached the correct range for compression rate and 29/40 (72.5%; 44.0±4.95 mm; 95% CI: 42.4-45.6 mm) the correct compression depth using the assisting device. Afterwards they conducted classic ECC without the device and deteriorated significantly: correct compression rate was achieved by 12/40 (30%, p≤0.0001; 110.6±11.0/min (95% CI: 107.1-114.1/min), while 25/40 (62.5%; 44.5±5.63 mm; 95% CI: 42.6-46.3 mm) met the correct compression depth. Group 2 performed poorer in ECC without assistance and 5/41 (12.2%; 104.5±21.35/min; 95% CI: 97.8-111.3/min) reached the correct rate whereas 21/41 (51.2%; 39.6±7.61 mm; 95% CI: 37.2-42.0 mm) compressed to the appropriate depth. Using the device there was a significant improvement in the second evaluation with 34/41 (82.9%, p≤0.0001; 101.7±4.68/min; 95% CI: 100.2-103.2/min) reaching the correct rate and 36/41 (87.8%, p≤0.0001; 43.9±4.16 mm; 95% CI: 42.6-45.2 mm) the correct depth.

conclusionsThe tested device is easy to use after instruction of less than 3 min and improves ECC performance of healthcare professionals in simulated cardiac arrest with respect to compression depth as well as compression rate.

Indexed as

Clinical CompetenceCardiopulmonary ResuscitationCross-Over StudiesEmergency Medical TechniciansFeedbackFemaleHeart ArrestHeart MassageHumansMaleManikinsMechanical PhenomenaNursesPhysiciansSurveys and Questionnaires

Identifiers

PMID21437754
OpenAlexW2180096212

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.