ArticleMedical physics2011
Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures.
Article in Medical physics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02737579 (XFM), which is not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
XFM: (X-ray Fused With MRI) Guided Cardiac Catheterization
Who cites it
8 citing papers in PubMed, 27 citations in OpenAlex.
- Development of a robust MRI fiducial system for automated fusion of MR-US abdominal images.Journal of applied clinical medical physics · 2018Article
- Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.Annals of biomedical engineering · 2017Article
- Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.International journal of computer assisted radiology and surgery · 2017Article
- X-ray Fused With Magnetic Resonance Imaging to Guide Endomyocardial Biopsy of a Right Ventricular Mass.Radiologic technology · 2016Article
- A method for registration of full-limb radiographs to knee MRI.Skeletal radiology · 2014Article
- Metal and complementary molecular bioimaging in Alzheimer's disease.Frontiers in aging neuroscience · 2014Review
- Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray.Medical physics · 2013Article
- Multimodality 3-dimensional image integration for congenital cardiac catheterization.Methodist DeBakey cardiovascular journalReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 2 countries.
Funding
Abstract
purposeIn X-ray fused with MRI, previously gathered roadmap MRI volume images are overlaid on live X-ray fluoroscopy images to help guide the clinician during an interventional procedure. The incorporation of MRI data allows for the visualization of soft tissue that is poorly visualized under X-ray. The widespread clinical use of this technique will require fully automating as many components as possible. While previous use of this method has required time-consuming manual intervention to register the two modalities, in this article, the authors present a fully automatic rigid-body registration method.
methodsExternal fiducial markers that are visible under these two complimentary imaging modalities were used to register the X-ray images with the roadmap MR images. The method has three components: (a) The identification of the 3D locations of the markers from a full 3D MR volume, (b) the identification of the 3D locations of the markers from a small number of 2D X-ray fluoroscopy images, and (c) finding the rigid-body transformation that registers the two point sets in the two modalities. For part (a), the localization of the markers from MR data, the MR volume image was thresholded, connected voxels were segmented and labeled, and the centroids of the connected components were computed. For part (b), the X-ray projection images, produced by an image intensifier, were first corrected for distortions. Binary mask images of the markers were created from the distortion-corrected X-ray projection images by applying edge detection, pattern recognition, and image morphological operations. The markers were localized in the X-ray frame using an iterative backprojection-based method which segments voxels in the volume of interest, discards false positives based on the previously computed edge-detected projections, and calculates the locations of the true markers as the centroids of the clusters of voxels that remain. For part (c), a variant of the iterative closest point method was used to find correspondences between and register the two sets of points computed from MR and X-ray data. This knowledge of the correspondence between the two point sets was used to refine, first, the X-ray marker localization and then the total rigid-body registration between modalities. The rigid-body registration was used to overlay the roadmap MR image onto the X-ray fluoroscopy projections.
resultsIn 35 separate experiments, the markers were correctly registered to each other in 100% of the cases. When half the number of X-ray projections was used (10 X-ray projections instead of 20), the markers were correctly registered in all 35 experiments. The method was also successful in all 35 experiments when the number of markers was (retrospectively) halved (from 16 to 8). The target registration error was computed in a phantom experiment to be less than 2.4 mm. In two in vivo experiments, targets (interventional devices with pointlike metallic structures) inside the heart were successfully registered between the two modalities.
conclusionsThe method presented can be used to automatically register a roadmap MR image to X-ray fluoroscopy using fiducial markers and as few as ten X-ray projections.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.