ArticleEuropean radiology2011
Low-dose triple-rule-out using 320-row-detector volume MDCT--less contrast medium and lower radiation exposure.
Article in European radiology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality.The international journal of cardiovascular imaging · 2013Trial
- Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes.The international journal of cardiovascular imaging · 2012Trial
- Single-Bolus Sequential Triple-Rule-Out CT Angiography: Image Quality and Radiation Dose on Wide-Area Detector and Dual-Source CT.Journal of clinical medicine · 2026Article
- Wide-Detector CT-Based optimized triple Rule-Out CT angiography for emergency chest pain: reducing contrast and radiation without compromising diagnostic quality.Emergency radiology · 2025Article
- The Role of Triple Rule-out CT in an Indian Emergency Setting.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2023Article
- Wide-volume versus helical acquisition in unenhanced chest CT: prospective intra-patient comparison of diagnostic accuracy and radiation dose in an ultra-low-dose setting.European radiology · 2019Article
- Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.Korean journal of radiology · 2019Review
- Advances in cardiac CT contrast injection and acquisition protocols.Cardiovascular diagnosis and therapy · 2017Article
- Low-tube-voltage selection for triple-rule-out CTA: relation to patient size.European radiology · 2017Article
- Triple Rule Out versus CT Angiogram Plus Stress Test for Evaluation of Chest Pain in the Emergency Department.The western journal of emergency medicine · 2015Observational
- Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT.European radiology · 2014Article
- Diagnostic accuracy and clinical outcomes of ECG-gated, whole chest CT in the emergency department.PloS one · 2013Article
- Insights into imaging of aortitis.Insights into imaging · 2012Article
- Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries.European radiology · 2012Article
- [Possibilities for exposure reduction in computed tomography examination of acute chest pain].Der Radiologe · 2012Article
- Coronary CT angiography: current status and continuing challenges.The British journal of radiology · 2012Review
- MDCT Derived Left Ventricular Function in Relation to Echocardiography: Validation and Revising the Role with the Evolving Technology.Journal of cardiovascular echographyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo investigate image quality of triple-rule-out (TRO) computed tomography (CT) using a 320-row-detector CT system with substantially reduced contrast medium volume at 100 kV.
methodsForty-six consecutive patients with noncritical, acute chest pain underwent 320-row-detector CT using a two-step TRO protocol consisting of a non-spiral, non-gated chest CT acquisition (150 mA) followed by a non-spiral, electrocardiography-gated cardiac acquisition (200-500 mA based on body mass index (BMI)). Data were acquired using a biphasic injection protocol with a total iodinated contrast medium volume of 60 ml (370 mg/ml). Vessel attenuation and effective doses were recorded. Image quality was scored independently by two readers.
resultsMean attenuation was 584 ± 114 Hounsfield units (HU) in the ascending aorta, 335 ± 63HU in the aortic arch, 658 ± 136HU in the pulmonary trunk, and 521 ± 97HU and 549 ± 102HU in the right and left coronary artery, respectively. In all but one patient, attenuation and image quality allowed accurate visualization of the pulmonary arteries, thoracic aorta, and coronary arteries in a single examination. Ninety-six percent of all coronary artery segments were rated diagnostic. Radiation exposure ranged between 2.0 and 3.3 mSv.
conclusionUsing 320-row-detector CT the investigated low-dose TRO protocol resulted in excellent opacification and image quality with substantial reduction of contrast medium volume compared to recently published TRO protocols.
Indexed as
Identifiers
21347640What OpenQuestion holds
Registered trials