ArticlePloS one2011
Single molecule fluorescence image patterns linked to dipole orientation and axial position: application to myosin cross-bridges in muscle fibers.
Article in PloS one, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 15 citations in OpenAlex.
- Resolving cargo-motor-track interactions with bifocal parallax single-particle tracking.Biophysical journal · 2021Article
- Auxotonic to isometric contraction transitioning in a beating heart causes myosin step-size to down shift.PloS one · 2017Article
- In vivo myosin step-size from zebrafish skeletal muscle.Open biology · 2016Article
- In vitro and in vivo single myosin step-sizes in striated muscle.Journal of muscle research and cell motility · 2015Article
- Optimized measurements of separations and angles between intra-molecular fluorescent markers.Nature communications · 2015Article
- In vivo orientation of single myosin lever arms in zebrafish skeletal muscle.Biophysical journal · 2014Article
- Extending single-molecule microscopy using optical Fourier processing.The journal of physical chemistry. B · 2014Article
- The role of molecular dipole orientation in single-molecule fluorescence microscopy and implications for super-resolution imaging.Chemphyschem : a European journal of chemical physics and physical chemistry · 2014Review
- Regulatory light chain mutants linked to heart disease modify the cardiac myosin lever arm.Biochemistry · 2013Article
- Evanescent field shapes excitation profile under axial epi-illumination.Journal of biomedical optics · 2012Article
- Single myosin cross-bridge orientation in cardiac papillary muscle detects lever-arm shear strain in transduction.Biochemistry · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
backgroundPhotoactivatable fluorescent probes developed specifically for single molecule detection extend advantages of single molecule imaging to high probe density regions of cells and tissues. They perform in the native biomolecule environment and have been used to detect both probe position and orientation. METHODS AND
findingsFluorescence emission from a single photoactivated probe captured in an oil immersion, high numerical aperture objective, produces a spatial pattern on the detector that is a linear combination of 6 independent and distinct spatial basis patterns with weighting coefficients specifying emission dipole orientation. Basis patterns are tabulated for single photoactivated probes labeling myosin cross-bridges in a permeabilized muscle fiber undergoing total internal reflection illumination. Emitter proximity to the glass/aqueous interface at the coverslip implies the dipole near-field and dipole power normalization are significant affecters of the basis patterns. Other characteristics of the basis patterns are contributed by field polarization rotation with transmission through the microscope optics and refraction by the filter set. Pattern recognition utilized the generalized linear model, maximum likelihood fitting, for Poisson distributed uncertainties. This fitting method is more appropriate for treating low signal level photon counting data than χ(2) minimization.
conclusionsResults indicate that emission dipole orientation is measurable from the intensity image except for the ambiguity under dipole inversion. The advantage over an alternative method comparing two measured polarized emission intensities using an analyzing polarizer is that information in the intensity spatial distribution provides more constraints on fitted parameters and a single image provides all the information needed. Axial distance dependence in the emission pattern is also exploited to measure relative probe position near focus. Single molecule images from axial scanning fitted simultaneously boost orientation and axial resolution in simulation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.