ArticleThe British journal of radiology2012
Brachial plexus assessment with three-dimensional isotropic resolution fast spin echo MRI: comparison with conventional MRI at 3.0 T.
Article in The British journal of radiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 38 citations in OpenAlex.
- Clinical benefits of enhanced 3D-NEVERview sequence in MRI simulation for nasopharyngeal carcinoma patients received radiotherapy.BMC cancer · 2025Article
- An optimized 1.5 Tesla MRI protocol of the brachial plexus.The neuroradiology journal · 2024Article
- The value of the cinematic volume rendering technique: magnetic resonance imaging in diagnosing tumors associated with the brachial plexus.European journal of medical research · 2023Article
- A pentavalent approach for the evaluation of traumatic brachial plexopathy on MRI: correlation of macropattern and micropattern.The British journal of radiology · 2023Review
- The guiding value of the cinematic volume rendering technique in the preoperative diagnosis of brachial plexus schwannoma.Frontiers in oncology · 2023Article
- Single-direction diffusion-weighted imaging may be a simple complementary sequence for evaluating fetal corpus callosum.European radiology · 2022Article
- The Application of Contrast-Enhanced 3D-STIR-VISTA MR Imaging of the Brachial Plexus.Journal of the Belgian Society of Radiology · 2022Article
- Magnetic resonance neurography appearance and diagnostic evaluation of peripheral nerve sheath tumors.Scientific reports · 2019Article
- Peripheral nerve imaging: Not only cross-sectional area.World journal of radiology · 2016Article
- High-Resolution 3-T Endorectal Prostate MRI: A Multireader Study of Radiologist Preference and Perceived Interpretive Quality of 2D and 3D T2-Weighted Fast Spin-Echo MR Images.AJR. American journal of roentgenology · 2016Article
- Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T.La Radiologia medica · 2016Article
- Diagnostic performance of the three-dimensional fast spin echo-Cube sequence in comparison with a conventional imaging protocol in evaluation of the lachrymal drainage system.European radiology · 2015Article
- MR imaging of the brachial plexus.Clinical neuroradiology · 2014Review
- High-resolution 3T MR neurography of the brachial plexus and its branches, with emphasis on 3D imaging.AJNR. American journal of neuroradiology · 2013Review
- 3 Tesla MR neurography--technique, interpretation, and pitfalls.Skeletal radiology · 2011Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe purpose of our study was to determine whether a three-dimensional (3D) isotropic resolution fast spin echo sequence (FSE-cube) has similar image quality and diagnostic performance to a routine MRI protocol for brachial plexus evaluation in volunteers and symptomatic patients at 3.0 T. Institutional review board approval and written informed consent were guaranteed.
methodsIn this prospective study FSE-cube was added to the standard brachial plexus examination protocol in eight patients (mean age, 50.2 years) with brachial plexus pathologies and in six volunteers (mean age, 54 years). Nerve visibility, tissue contrast, edge sharpness, image blurring, motion artefact and acquisition time were calculated for FSE-cube sequences and for the standard protocol on a standardised five-point scale. The visibility of brachial plexus nerve and surrounding tissues at four levels (roots, interscalene area, costoclavicular space and axillary level) was assessed.
resultsImage quality and nerve visibility did not significantly differ between FSE-cube and the standard protocol (p>0.05). Acquisition time was statistically and clinically significantly shorter with FSE-cube (p<0.05). Pathological findings were seen equally well with FSE-cube and the standard protocol.
conclusion3D FSE-cube provided similar image quality in a shorter acquisition time and enabled excellent visualisation of brachial plexus anatomy and pathology in any orientation, regardless of the original scanning plane.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials