High-resolution 3D X-ray imaging of intracranial nitinol stents.
Article in Neuroradiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment.AJNR. American journal of neuroradiology · 2014Trial
- Image Quality and Radiation Dose of Conventional and Wide-Field High-Resolution Cone-Beam Computed Tomography for Cerebral Angiography: A Phantom Study.Tomography (Ann Arbor, Mich.) · 2023Article
- Investigation of Stent Prototypes for the Eustachian Tube in Human Donor Bodies.Bioengineering (Basel, Switzerland) · 2023Article
- Radiation dose and image quality comparison during spine surgery with two different, intraoperative 3D imaging navigation systems.Journal of applied clinical medical physics · 2019Article
- Usefulness of Cone Beam Intra-Arterial CTA for Evaluation of Flow Diverters: A Practical Approach for Daily Use.Interventional neurology · 2018Article
- Quantitative analysis of high-resolution, contrast-enhanced, cone-beam CT for the detection of intracranial in-stent hyperplasia.Journal of neurointerventional surgery · 2015Article
- Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark.Neuroradiology · 2014Article
- Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?Neuroradiology · 2013Article
- Intravenous flat-detector CT angiography in acute ischemic stroke management.Neuroradiology · 2012Article
- Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.AJNR. American journal of neuroradiologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTo assess an optimized 3D imaging protocol for intracranial nitinol stents in 3D C-arm flat detector imaging. For this purpose, an image quality simulation and an in vitro study was carried out.
methodsNitinol stents of various brands were placed inside an anthropomorphic head phantom, using iodine contrast. Experiments with objects were preceded by image quality and dose simulations. We varied X-ray imaging parameters in a commercially interventional X-ray system to set 3D image quality in the contrast-noise-sharpness space. Beam quality was varied to evaluate contrast of the stents while keeping absorbed dose below recommended values. Two detector formats were used, paired with an appropriate pixel size and X-ray focus size. Zoomed reconstructions were carried out and snapshot images acquired. High contrast spatial resolution was assessed with a CT phantom.
resultsWe found an optimal protocol for imaging intracranial nitinol stents. Contrast resolution was optimized for nickel-titanium-containing stents. A high spatial resolution larger than 2.1 lp/mm allows struts to be visualized. We obtained images of stents of various brands and a representative set of images is shown. Independent of the make, struts can be imaged with virtually continuous strokes. Measured absorbed doses are shown to be lower than 50 mGy Computed Tomography Dose Index (CTDI).
conclusionBy balancing the modulation transfer of the imaging components and tuning the high-contrast imaging capabilities, we have shown that thin nitinol stent wires can be reconstructed with high contrast-to-noise ratio and good detail, while keeping radiation doses within recommended values. Experimental results compare well with imaging simulations.