Evidence map›Paper›PMID 21331120›Full record

ArticleSeminars in interventional radiology2004

Pharmacomechanical Thrombolysis of Dialysis Access Grafts Using the MTI Castañeda Over-the-Wire Brush Catheter and Reteplase.

Alexjandro Mendez-Castillo, Syed Hassain, Flavio Castañeda

Open access · bronzeAbstract read
In one paragraph

Article in Seminars in interventional radiology, 2004. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 86% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Alexjandro Mendez-CastilloRadiology Department, University of Illinois College of Medicine at Peoria, Peoria, Illinois.
Syed Hassain
Flavio Castañeda
Illinois College · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pharmacomechanical thrombolysis (PMT) has emerged as an alternate treatment used in most patients presenting with a thrombosed hemodialysis graft. Although the gold standard, surgical revision of thrombosed hemodialysis grafts is reserved for those cases of recurrent thrombosis despite the use of percutaneous techniques and for complicated cases after PMT. Nevertheless, as for every other procedure, PMT has its own set of limitations and cost issues. New mechanical devices have begun to emerge on the market to help accelerate clot dissolution with or without thrombolytic medications. These devices have decreased the time required to lyse clot and decrease the overall cost of percutaneous treatment. This article describes the use of the Microtherapeutics, Inc. (MTI) Castañeda over-the-wire brush and our experience with this device in the treatment of the clotted hemodialysis graft.

Indexed as

Dialysisinterventionthrombolysis

Identifiers

PMID21331120
PMCPMC3036210
OpenAlexW2053498599

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.