ArticleInternational orthopaedics2011
Total hip replacement with an uncemented Wagner cone stem for patients with congenital hip dysplasia.
Article in International orthopaedics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Developmental hip dysplasia treated by total hip arthroplasty using a cementless Wagner cone stem in young adult patients with a small physique.BMC musculoskeletal disorders · 2017Trial
- Three-years comparative outcomes of S-ROM versus Wagner cone prostheses in total hip arthroplasty with subtrochanteric osteotomy for Crowe IV hip dysplasia.Archives of orthopaedic and trauma surgery · 2025Article
- A Modified Wagner Stem Design Increases the Primary Stability in Cementless Revision Hip Arthroplasty.Arthroplasty today · 2025Article
- Single-Taper Conical Tapered Stem in Total Hip Arthroplasty for Primary Osteoarthritis: A Comparative Long-Term Registry Evaluation.Journal of clinical medicine · 2024Article
- Cementless total hip arthroplasty for failed treatment of subtrochanteric fracture.BMC musculoskeletal disorders · 2021Article
- Comparison of two different on-shelf femoral stems for Crowe type IV developmental dysplasia of the hip.The Journal of international medical research · 2020Article
- [Total hip arthroplasty with Wagner Cone stem and subtrochanteric shortening osteotomy in treatment of CroweZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2019Article
- Current concepts in developmental dysplasia of the hip and Total hip arthroplasty.Arthroplasty (London, England) · 2019Review
- Long-term survival of the cemented Müller CDH stem: a minimum follow-up of 10 years.Archives of orthopaedic and trauma surgery · 2018Article
- Can a Conical Implant Successfully Address Complex Anatomy in Primary THA? Radiographs and Hip Scores at Early Followup.Clinical orthopaedics and related research · 2016Article
- The ratio of femoral head diameter to pelvic height in the normal hips of a Chinese population.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2014Article
- Challenging Implantation of Hip Prosthesis in a 32-year-old Patient with Kniest Syndrome.Journal of orthopaedic case reportsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to review retrospectively the cases operated upon in our department in recent years with a Wagner stem and a small socket in cases of Crowe I or II dysplastic hips.
methodsWe conducted a retrospective clinical radiological review of 30 hips diagnosed with hip dysplasia Crowe I or II treated in our centre between 2002 and 2008. All of them were treated with a Wagner cone stem and a small Trilogy acetabulum (Zimmer ®).
resultsThere were 15 men and 11 women with 13 left and 17 right femurs. Mean follow-up was 43.44 months (range 14-87). Eight patients were Crowe I type and 22 were Crowe II type. Merlé d'Aubigne score pre-operatively was 12.23 and at the last follow-up was 15.54. Mean leg length inequality was 1.79 and after surgery it was 0.69 cm. Complications included three infection and three dislocations (two of them in the same patient).
conclusionsThe use of a Wagner stem is a good option to correct the different deformities in the proximal femur in these cases. A small socket allows a correct relocation of the acetabulum in a dysplastic socket with good bone coverage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.