Trial reportJournal of diabetes science and technology2011
Performance of the CONTOUR® TS Blood Glucose Monitoring System.
Trial report in Journal of diabetes science and technology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 14 citations in OpenAlex.
- Accuracy and User Performance of a New Blood Glucose Monitoring System.Journal of diabetes science and technology · 2021Article
- Chronic consumption of sweeteners in mice and its effect on the immune system and the small intestine microbiotaBiomedica : revista del Instituto Nacional de Salud · 2021Article
- Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis.Biosensors · 2018Review
- System accuracy evaluation of the GlucoRx nexus voice TD-4280 blood glucose monitoring system.Disease markers · 2014Article
- Higher accuracy of self-monitoring of blood glucose in insulin-treated patients in Germany: clinical and economical aspects.Journal of diabetes science and technology · 2013Article
- Accuracy of the CONTOUR® blood glucose monitoring system.Journal of diabetes science and technology · 2011Article
- Analysis of the performance of the CONTOUR® TS Blood Glucose Monitoring System: when regulatory performance criteria are met, should we have confidence to use a medical device with all patients?Journal of diabetes science and technology · 2011Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSelf-monitoring of blood glucose (SMBG) remains an important component of diabetes management, engendering a need for affordable blood glucose (BG) meters that are accurate, precise, and convenient. The CONTOUR® TS is a BG meter that endeavors to meet this need. It uses glucose dehydrogenase/flavin dinucleotide chemistry, automatic test strip calibration, and autocompensation for hematocrit along with the ease of use that has come to be expected of a modern meter. The objective of this clinical trial was to determine whether the CONTOUR TS system met these criteria.
methodsThe system was evaluated at a single clinical site with 106 subjects with type 1 or type 2 diabetes. Blood glucose values ranged from 60 to 333 mg/dl over all subjects. Both lay users and health care professionals (HCPs) tested the meters, with test strips from three different lots. Results were compared to a reference analyzer of verified precision and accuracy. Forty-nine of the subjects also participated in a home study of the meter. Lay users learned to use the system without assistance and were surveyed on its use at the end of the study.
resultsWhen used with capillary blood, both subjects and HCPs obtained results that exceeded the International Organization for Standardization 15197:2003 criteria, (i.e., ≥95% of values fell within 20% or 15 mg/dl of the laboratory value for BG levels greater than or less than 75 mg/dl, respectively). Specifically, lay users achieved 97.9% and HCPs 98.6%. When used with venous blood, 99.8% of measurements were within the criteria. All measurements for both capillary and venous blood fell into zones A or B of the Parkes error grid, deemed clinically accurate. Hematocrit was found to have no influence on BG measurements. A large majority of the subjects found the system easy to learn and to use.
conclusionsThe CONTOUR TS BG meter system gave accurate and reproducible results with both capillary and venous blood; subjects learned to use the meter system by following the user guide and quick reference guide.
Indexed as